Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/41696
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Prado, A. J. | - |
dc.contributor.author | Kurokawa, S. | - |
dc.contributor.author | Costa, E. C. M. | - |
dc.contributor.author | Pissolato Filho, J. | - |
dc.contributor.author | Bovolato, L. F. | - |
dc.date.accessioned | 2014-05-20T15:32:55Z | - |
dc.date.accessioned | 2016-10-25T18:09:19Z | - |
dc.date.available | 2014-05-20T15:32:55Z | - |
dc.date.available | 2016-10-25T18:09:19Z | - |
dc.date.issued | 2012-01-01 | - |
dc.identifier | http://dx.doi.org/10.1109/PESGM.2012.6345288 | - |
dc.identifier.citation | 2012 IEEE Power and Energy Society General Meeting. New York: IEEE, p. 6, 2012. | - |
dc.identifier.uri | http://hdl.handle.net/11449/41696 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/41696 | - |
dc.description.abstract | The results presented in this paper are based on a research about the application of approximated transformation matrices for electromagnetic transient analyses and simulations in transmission lines. Initially, it has developed the application of a single real transformation matrix for a double three-phase transmission lines, because the symmetry of the distribution of the phase conductors and the ground wires. After this, the same type of transformation matrix has applied for symmetrical single three-phase transmission lines. Analyzing asymmetrical single three-phase lines, it has used three different line configurations. For these transmission line types, the errors between the eigenvalues and the approximated results, called quasi modes, have been considered negligible. on the other hand, the quasi mode eigenvalue matrix for each case was not a diagonal one. and the relative values of the off-diagonal elements of the approximated quasi mode matrix are not negligible, mainly for the low frequencies. Based on this problem, a correction procedure has been applied for minimizing the mentioned relative values. For the correction procedure application, symmetrical and asymmetrical single three-phase transmission line samples have been used. Checking the correction procedure results, analyses and simulations have been carried out in mode and time domain. In this paper, the last results of mentioned research are presented and they related to the time domain simulations. | en |
dc.format.extent | 6 | - |
dc.language.iso | eng | - |
dc.publisher | IEEE | - |
dc.source | Web of Science | - |
dc.subject | Clarke's matrix | en |
dc.subject | eigenvector | en |
dc.subject | eigenvalue | en |
dc.subject | phase mode transformation | en |
dc.subject | error analysis | en |
dc.subject | non symmetrical lines | en |
dc.subject | frequency dependent parameters | en |
dc.title | Time Domain Analyses for Three-phase Lines with Corrected Modal Transformation Matrix | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.description.affiliation | Univ São Paulo State, Dept Elect Engn, FEIS UNESP, São Paulo, Brazil | - |
dc.description.affiliationUnesp | Univ São Paulo State, Dept Elect Engn, FEIS UNESP, São Paulo, Brazil | - |
dc.identifier.wos | WOS:000312493704131 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | 2012 IEEE Power and Energy Society General Meeting | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.