dc.contributor.authorFreschi, Gian Paulo G.-
dc.contributor.authorFreschi, Carolina D.-
dc.contributor.authorNeto, Jose A. Gomes-
dc.date.accessioned2014-05-20T15:33:34Z-
dc.date.accessioned2016-10-25T18:10:11Z-
dc.date.available2014-05-20T15:33:34Z-
dc.date.available2016-10-25T18:10:11Z-
dc.date.issued2008-04-01-
dc.identifierhttp://dx.doi.org/10.1007/s00604-007-0884-y-
dc.identifier.citationMicrochimica Acta. Wien: Springer Wien, v. 161, n. 1-2, p. 129-135, 2008.-
dc.identifier.issn0026-3672-
dc.identifier.urihttp://hdl.handle.net/11449/42159-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/42159-
dc.description.abstractDifferent kinds of modifiers and coatings on the integrated platform of transversely heated graphite atomizer (THGA) have been tested for the simultaneous determination of two group of elements: the first, the more volatile, formed by arsenic, bismuth, lead, antimony and selenium; the second, the less volatile, formed by cobalt, chromium, cupper, iron and manganese in milk by electrothermal atomic absorption spectrometry. Different Rh-modifiers were studied, such as Rh-coated platforms (Rh), carbide plus rhodium coated platforms (W-Rh, Zr-Rh), carbide-coated platforms (W and Zr) with co-injection of RhCl3, solutions and uncoated platforms with injection of solutions of Pd(NO3)(2), Mg(NO3)(2), and RhCl3. Milk samples were diluted 1:10 in 1.0% HNO3 and injected into the tube. The mass of modifier deposited and co-injected in the tube and the use of end capped tubes were also evaluated in order to improve the electrothermal behavior of analytes. Integrated platform pretreated with W plus co-injection RhCl3 for first group and pretreated with W-Rh for second group were elected. For 20 mu L injected samples the analytical curves in the 5.0-20.0 mu g L-1 concentration range have good linear correlation coefficients (r > 0.998). Relative standard deviations (n = 12) are < 6% and the calculated characteristic masses are between 5 pg and 62 pg.en
dc.format.extent129-135-
dc.language.isoeng-
dc.publisherSpringer Wien-
dc.sourceWeb of Science-
dc.subjectmilken
dc.subjectsimultaneous determinationen
dc.subjectETAASen
dc.subjectrhodiumen
dc.subjectmodifiersen
dc.titleEvaluation of different rhodium modifiers and coatings on the simultaneous determination of As, Bi, Pb, Sb, Se and of Co, Cr, Cu, Fe, Mn in milk by electrothermal atomic absorption spectrometryen
dc.typeoutro-
dc.contributor.institutionUniversidade Federal da Grande Dourados (UFGD)-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationFundação Univ Fed Grande Dourados, Fac Ciencias Exatas & Tecnol, BR-79804970 Dourados, MS, Brazil-
dc.description.affiliationUniv Estadual Paulista, Inst Quim, BR-14801970 Araraquara, SP, Brazil-
dc.description.affiliationUnespUniv Estadual Paulista, Inst Quim, BR-14801970 Araraquara, SP, Brazil-
dc.identifier.doi10.1007/s00604-007-0884-y-
dc.identifier.wosWOS:000255742400012-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofMicrochimica Acta-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.