Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/42539
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Granada Echeverri, Mauricio | - |
dc.contributor.author | Rider Flores, Marcos Julio | - |
dc.contributor.author | Mantovani, Jose Roberto S. | - |
dc.date.accessioned | 2014-05-20T15:34:24Z | - |
dc.date.accessioned | 2016-10-25T18:10:56Z | - |
dc.date.available | 2014-05-20T15:34:24Z | - |
dc.date.available | 2016-10-25T18:10:56Z | - |
dc.date.issued | 2010-06-01 | - |
dc.identifier | http://revistas.unal.edu.co/index.php/dyna/article/view/15896 | - |
dc.identifier.citation | Dyna-colombia. Medellin: Univ Nac Colombia, Fac Nac Minas, v. 77, n. 162, p. 303-312, 2010. | - |
dc.identifier.issn | 0012-7353 | - |
dc.identifier.uri | http://hdl.handle.net/11449/42539 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/42539 | - |
dc.description.abstract | This paper applies two methods of mathematical decomposition to carry out an optimal reactive power flow (ORPF) in a coordinated decentralized way in the context of an interconnected multi-area power system. The first method is based on an augmented Lagrangian approach using the auxiliary problem principle (APP). The second method uses a decomposition technique based on the Karush-Kuhn-Tucker (KKT) first-order optimality conditions. The viability of each method to be used in the decomposition of multi-area ORPF is studied and the corresponding mathematical models are presented. The IEEE RTS-96, the IEEE 118-bus test systems and a 9-bus didactic system are used in order to show the operation and effectiveness of the decomposition methods. | en |
dc.format.extent | 303-312 | - |
dc.language.iso | spa | - |
dc.publisher | Univ Nac Colombia, Fac Nac Minas | - |
dc.source | Web of Science | - |
dc.subject | Decentralized coordination | en |
dc.subject | decomposition methods | en |
dc.subject | multi-area power systems | en |
dc.subject | optimal reactive power flow | en |
dc.subject | ORPF | en |
dc.subject | VAR planning | en |
dc.title | TWO DECOMPOSITION APPROACHES APPLIED TO THE MULTI-AREA OPTIMAL REACTIVE POWER FLOW PROBLEM | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual de Campinas (UNICAMP) | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.description.affiliation | Univ Estadual Campinas, Dept Sistemas Energia Elect, BR-13081970 Campinas, SP, Brazil | - |
dc.description.affiliation | UNESP, Escuela Ingn, Ilha Solteira, Brazil | - |
dc.description.affiliationUnesp | UNESP, Escuela Ingn, Ilha Solteira, Brazil | - |
dc.identifier.wos | WOS:000279891900011 | - |
dc.rights.accessRights | Acesso aberto | - |
dc.identifier.file | WOS000279891900011.pdf | - |
dc.relation.ispartof | Dyna-colombia | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.