You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/63730
Full metadata record
DC FieldValueLanguage
dc.contributor.authorDe Andrade, João Carlos-
dc.contributor.authorRochat, Julio Cesar-
dc.contributor.authorBaccan, Nivaldo-
dc.date.accessioned2014-05-27T00:35:18Z-
dc.date.accessioned2016-10-25T18:12:01Z-
dc.date.available2014-05-27T00:35:18Z-
dc.date.available2016-10-25T18:12:01Z-
dc.date.issued1985-12-01-
dc.identifierhttp://dx.doi.org/10.1039/AN9851000197-
dc.identifier.citationThe Analyst, v. 110, n. 2, p. 197-199, 1985.-
dc.identifier.issn0003-2654-
dc.identifier.urihttp://hdl.handle.net/11449/63730-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/63730-
dc.description.abstractA flow injection analysis (FIA) procedure for the speciation of Cr(III) and Cr(VI) using the 1,5-diphenylcarbazide (DPC) method is presented. As Cr(III) does not interfere in the Cr(VI) - DPC reaction, both Cr(VI) and total chromium [after the on-line oxidation of Cr(III) by Ce(IV)] are sequentially determined. Cr(III) is obtained by difference. Under the experimental conditions described, the calibration graphs are linear up to 2 μg mh1 of Cr(VI) and 4 μg ml-1 of Cr(III). The detection limits found were 18 ng ml -1 for Cr(VI) and 55 ng ml-1 for Cr(III), at a signal to noise ratio of 3. The common interfering elements in the Cr(VI) - DPC reaction were investigated under dynamic FIA conditions. The FIA method was also compared with the conventional spectrophotometric procedure.en
dc.format.extent197-199-
dc.language.isoeng-
dc.sourceScopus-
dc.subjectChromium determination-
dc.subjectChromium speciation-
dc.subjectFlow injection analysis-
dc.subjectSpectrophotometry-
dc.titleSequential spectrophotometric determination of chromium(III) and chromium(VI) using flow injection analysisen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual de Campinas (UNICAMP)-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationUniversidade Estadual de Campinas Institute de Quimica, C.P. 6154, 13100 Campinas, SP-
dc.description.affiliationUniversidade Estadual Paulista Institute de Qufmica, 14800, Araraquara, SP-
dc.description.affiliationUnespUniversidade Estadual Paulista Institute de Qufmica, 14800, Araraquara, SP-
dc.identifier.doi10.1039/AN9851000197-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofThe Analyst-
dc.identifier.scopus2-s2.0-2542529820-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.