Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/63953
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Bretan, Onivaldo | - |
dc.contributor.author | Henry, Maria Aparecida Coelho de Arruda | - |
dc.contributor.author | Cury, P. R. | - |
dc.date.accessioned | 2014-05-27T07:37:51Z | - |
dc.date.accessioned | 2016-10-25T18:12:25Z | - |
dc.date.available | 2014-05-27T07:37:51Z | - |
dc.date.available | 2016-10-25T18:12:25Z | - |
dc.date.issued | 1990-01-01 | - |
dc.identifier | http://dx.doi.org/10.1001/archotol.1990.01870080036010 | - |
dc.identifier.citation | Archives of Otolaryngology - Head and Neck Surgery, v. 116, n. 8, p. 914-916, 1990. | - |
dc.identifier.issn | 0886-4470 | - |
dc.identifier.uri | http://hdl.handle.net/11449/63953 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/63953 | - |
dc.description.abstract | The various pull-through techniques used to measure pressure and length of the upper esophageal sphincter have not been studied in depth. Because of the importance of obtaining further information about these techniques, a group of 25 dogs was submitted to upper esophageal sphincter pressure and length measurements by three different pull-through techniques (two of the continuous type and one of the station type), each with three replications per animal, to determine possible differences among techniques. A single introduction provided reliable results, with no sequential effect of the measurements or of any one technique on resting pressure. However, each technique yielded different sphincter lengths, higher values being obtained when the continuous techniques were used. | en |
dc.format.extent | 914-916 | - |
dc.language.iso | eng | - |
dc.source | Scopus | - |
dc.subject | animal experiment | - |
dc.subject | diagnosis | - |
dc.subject | dog | - |
dc.subject | esophagus | - |
dc.subject | lower esophagus sphincter | - |
dc.subject | male | - |
dc.subject | manometry | - |
dc.subject | methodology | - |
dc.subject | priority journal | - |
dc.subject | Animal | - |
dc.subject | Comparative Study | - |
dc.subject | Dogs | - |
dc.subject | Esophagogastric Junction | - |
dc.subject | Male | - |
dc.subject | Manometry | - |
dc.title | Techniques in electromanometry of the upper esophageal sphincter | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.identifier.doi | 10.1001/archotol.1990.01870080036010 | - |
dc.identifier.wos | WOS:A1990DT07500003 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | Archives of Otolaryngology - Head and Neck Surgery | - |
dc.identifier.scopus | 2-s2.0-0025282129 | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.