Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/64070
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Machado Cucci, A. L. | - |
dc.contributor.author | Fuller, J. B. | - |
dc.contributor.author | Giampaolo, E. T. | - |
dc.contributor.author | Leonardi, P. | - |
dc.date.accessioned | 2014-05-27T11:15:16Z | - |
dc.date.accessioned | 2016-10-25T18:12:37Z | - |
dc.date.available | 2014-05-27T11:15:16Z | - |
dc.date.available | 2016-10-25T18:12:37Z | - |
dc.date.issued | 1990-12-01 | - |
dc.identifier | http://www.revodontolunesp.com.br/articles/view/id/51ae4a9b1ef1faca3d0021b8 | - |
dc.identifier.citation | Revista de Odontologia da UNESP, v. 19, n. 1, p. 251-258, 1990. | - |
dc.identifier.issn | 0101-1774 | - |
dc.identifier.uri | http://hdl.handle.net/11449/64070 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/64070 | - |
dc.description.abstract | The authors tested the T clasp of Roach in three differents proportions among width and thickness: E1-1.7; E2-2.0 and E3-2.3, with a constant length of 15 mm. These clasps were casted with three cobalt-chromium alloys (L1-Biosil; L2-Steldent and L3-Duracrom), through two casting techniques (F1-oxygen-gas and F2-oxygen-acetylene). The fatigue of the clasps were verified by using and assay machine, that through movements, simulate the insertion and removal of the clasps for a pattern which were obtained from a premolar, prepared in a surveyor. This machine detect the fatigue of the clasps and count the number of cycles of insertion and removal realized. The obtained results of the interaction between the analysed factors, were submitted to the statistic analysis and the authors concluded that: a) the interaction of factors, Alloy x Thickness, Alloy x Casting Technique and Thickness x Casting Technique did not change the order of effects that the factors showed separately but gave rise to effects of different magnitude for any observed sense; b) the simultaneous interaction of the factors Alloy x Thickness x Casting Technique confirmed the superiority of the L3 alloy, the thickness E3 and the F2 casting technique. | en |
dc.format.extent | 251-258 | - |
dc.language.iso | por | - |
dc.source | Scopus | - |
dc.subject | chromium derivative | - |
dc.subject | denture | - |
dc.subject | human | - |
dc.subject | materials testing | - |
dc.subject | premolar tooth | - |
dc.subject | Bicuspid | - |
dc.subject | Chromium Alloys | - |
dc.subject | Dental Casting Technique | - |
dc.subject | Denture Retention | - |
dc.subject | English Abstract | - |
dc.subject | Human | - |
dc.subject | Materials Testing | - |
dc.title | Fadiga de grampos de retenção em prótese parcial removível. Efeito de ligas, espessuras e técnicas de fusão. Parte II. | pt |
dc.title.alternative | Fatigue of retentive clasps of removable partial dentures. Effect of alloys, thickness and casting techniques. 2 | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.rights.accessRights | Acesso aberto | - |
dc.identifier.file | 2-s2.0-0025540654.pdf | - |
dc.relation.ispartof | Revista de Odontologia da UNESP | - |
dc.identifier.scopus | 2-s2.0-0025540654 | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.