You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/64070
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMachado Cucci, A. L.-
dc.contributor.authorFuller, J. B.-
dc.contributor.authorGiampaolo, E. T.-
dc.contributor.authorLeonardi, P.-
dc.date.accessioned2014-05-27T11:15:16Z-
dc.date.accessioned2016-10-25T18:12:37Z-
dc.date.available2014-05-27T11:15:16Z-
dc.date.available2016-10-25T18:12:37Z-
dc.date.issued1990-12-01-
dc.identifierhttp://www.revodontolunesp.com.br/articles/view/id/51ae4a9b1ef1faca3d0021b8-
dc.identifier.citationRevista de Odontologia da UNESP, v. 19, n. 1, p. 251-258, 1990.-
dc.identifier.issn0101-1774-
dc.identifier.urihttp://hdl.handle.net/11449/64070-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/64070-
dc.description.abstractThe authors tested the T clasp of Roach in three differents proportions among width and thickness: E1-1.7; E2-2.0 and E3-2.3, with a constant length of 15 mm. These clasps were casted with three cobalt-chromium alloys (L1-Biosil; L2-Steldent and L3-Duracrom), through two casting techniques (F1-oxygen-gas and F2-oxygen-acetylene). The fatigue of the clasps were verified by using and assay machine, that through movements, simulate the insertion and removal of the clasps for a pattern which were obtained from a premolar, prepared in a surveyor. This machine detect the fatigue of the clasps and count the number of cycles of insertion and removal realized. The obtained results of the interaction between the analysed factors, were submitted to the statistic analysis and the authors concluded that: a) the interaction of factors, Alloy x Thickness, Alloy x Casting Technique and Thickness x Casting Technique did not change the order of effects that the factors showed separately but gave rise to effects of different magnitude for any observed sense; b) the simultaneous interaction of the factors Alloy x Thickness x Casting Technique confirmed the superiority of the L3 alloy, the thickness E3 and the F2 casting technique.en
dc.format.extent251-258-
dc.language.isopor-
dc.sourceScopus-
dc.subjectchromium derivative-
dc.subjectdenture-
dc.subjecthuman-
dc.subjectmaterials testing-
dc.subjectpremolar tooth-
dc.subjectBicuspid-
dc.subjectChromium Alloys-
dc.subjectDental Casting Technique-
dc.subjectDenture Retention-
dc.subjectEnglish Abstract-
dc.subjectHuman-
dc.subjectMaterials Testing-
dc.titleFadiga de grampos de retenção em prótese parcial removível. Efeito de ligas, espessuras e técnicas de fusão. Parte II.pt
dc.title.alternativeFatigue of retentive clasps of removable partial dentures. Effect of alloys, thickness and casting techniques. 2en
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.rights.accessRightsAcesso aberto-
dc.identifier.file2-s2.0-0025540654.pdf-
dc.relation.ispartofRevista de Odontologia da UNESP-
dc.identifier.scopus2-s2.0-0025540654-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.