Você está no menu de acessibilidade

Utilize este identificador para citar ou criar um link para este item: http://acervodigital.unesp.br/handle/11449/65252
Registro de metadados completo
Campo DCValorIdioma
dc.contributor.authorScaf, Gulnara-
dc.contributor.authorLurie, Alan G.-
dc.contributor.authorMosier, Kristine M.-
dc.contributor.authorKantor, Mel L.-
dc.contributor.authorRamsby, Gale R.-
dc.contributor.authorFreedman, Michael L.-
dc.date.accessioned2014-05-27T11:18:17Z-
dc.date.accessioned2016-10-25T18:14:43Z-
dc.date.available2014-05-27T11:18:17Z-
dc.date.available2016-10-25T18:14:43Z-
dc.date.issued1997-12-01-
dc.identifierhttp://dx.doi.org/10.1016/S1079-2104(97)90089-5-
dc.identifier.citationOral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontics, v. 83, n. 1, p. 41-48, 1997.-
dc.identifier.issn1079-2104-
dc.identifier.urihttp://hdl.handle.net/11449/65252-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/65252-
dc.description.abstractThermoluminescent dosimeters were used to measure radiation doses at craniofacial sites in a tissue-equivalent phantom during film-based multidirectional tomography with the Tomax Ultrascan (Incubation Industries, Ivyland, Pa.) and during computed tomography with the Elscint Excel 2400 (Elscint Corp., Tel Aviv, Israel). Mean absorbed doses for presurgical mandibular and maxillary canine and molar implant assessments were converted to equivalent doses, which were then multipied by published weighting factors and summed to give effective doses. The computed tomgraphy device consistently delivered higher doses than the Tomax Ultrascan to all anatomic locations; the differences were most pronounced when only one or two implant sites were evaluated. The reasons for the dose disparities are considered both anatomically and procedurally. A survey of examination cost revealed film-based multidirectional tomography to be less expensive than computed tomography.en
dc.format.extent41-48-
dc.language.isoeng-
dc.sourceScopus-
dc.titleDosimetry and cost of imaging osseointegrated implants with film-based and computed tomographyen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionUniversity of Connecticut Health Center (UCHC)-
dc.contributor.institutionNew Jersey Dental School (UMDNJ)-
dc.description.affiliationOral and Maxillofacial Radiol. Div. Faculdade Odontol. Araraquara-UNESP, Sao Paulo-
dc.description.affiliationDiv. Oral and Maxillofacial Radiol. Department of Oral Diagnosis Univ. of Connecticut Health Center, Farmington, CT-
dc.description.affiliationDiv. Oral and Maxillofacial Radiol. UMDNJ-New Jersey Dental School, Newark, NJ-
dc.description.affiliationDepartment of Radiology School of Medicine Univ. of Connecticut Health Center, Farmington, CT-
dc.description.affiliationDepartment of Oral Diagnosis Univ. of Connecticut Health Center School of Dental Medicine, 263 Farmington Avenue, Farmington, CT 06030-1605-
dc.description.affiliationUnespOral and Maxillofacial Radiol. Div. Faculdade Odontol. Araraquara-UNESP, Sao Paulo-
dc.identifier.doi10.1016/S1079-2104(97)90089-5-
dc.identifier.wosWOS:A1997WD10200013-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofOral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontics-
dc.identifier.scopus2-s2.0-0030637063-
Aparece nas coleções:Artigos, TCCs, Teses e Dissertações da Unesp

Não há nenhum arquivo associado com este item.
 

Itens do Acervo digital da UNESP são protegidos por direitos autorais reservados a menos que seja expresso o contrário.