dc.description.abstractSTATEMENT OF PROBLEM: Because water sorption of autopolymerizing acrylic reline resins is accompanied by volumetric change, it is a physical property of importance. As residual monomer leaches into the oral fluids and causes tissue irritation, low solubility of these resins is desired. Another requirement is a satisfactory bond between the autopolymerizing acrylic resins and the denture base acrylic resin. PURPOSE: This study compared the water sorption, solubility, and the transverse bond strength of 2 autopolymerizing acrylic resins (Duraliner II and Kooliner) and 1 heat-polymerizing acrylic resin (Lucitone 550). MATERIAL AND METHODS: The water sorption and solubility test was performed as per International Standards Organization Specification No. 1567 for denture base polymers. Bond strengths between the autopolymerizing acrylic resins and the heat-polymerizing acrylic resin were determine with a 3-point loading test made on specimens immersed in distilled water at 37 degrees C for 50 hours and for 30 days. Visual inspection determined whether failures were adhesive or cohesive. RESULTS: Duraliner II acrylic resin showed significantly lower water sorption than Kooliner and Lucitone 550 acrylic resins. No difference was noted in the solubility of all materials. Kooliner acrylic resin demonstrated significantly lower transverse bond strength to denture base acrylic resin and failed adhesively. The failures seen with Duraliner II acrylic resin were primarily cohesive in nature. CONCLUSIONS: Autopolymerizing acrylic reline resins met water sorption and solubility requirements. However, Kooliner acrylic resin demonstrated significantly lower bond strength to denture base acrylic resin.en
dc.format.extent434-438-
dc.language.isoeng-
dc.sourceScopus-
dc.subjectacrylic acid resin-
dc.subjectduraliner II-
dc.subjectkooliner-
dc.subjectLucitone-
dc.subjectwater-
dc.subjectabsorption-
dc.subjectadsorption-
dc.subjectanalysis of variance-
dc.subjectchemistry-
dc.subjectcomparative study-
dc.subjectdental bonding-
dc.subjectdenture-
dc.subjectheat-
dc.subjecthuman-
dc.subjectmaterials testing-
dc.subjectmechanical stress-
dc.subjectsolubility-
dc.subjectsurface property-
dc.subjecttime-
dc.subjectAbsorption-
dc.subjectAcrylic Resins-
dc.subjectAdsorption-
dc.subjectAnalysis of Variance-
dc.subjectDental Bonding-
dc.subjectDenture Bases-
dc.subjectDenture Rebasing-
dc.subjectHeat-
dc.subjectHumans-
dc.subjectMaterials Testing-
dc.subjectSolubility-
dc.subjectStress, Mechanical-
dc.subjectSurface Properties-
dc.subjectTime Factors-
dc.subjectWater-
dc.titleWater sorption, solubility, and bond strength of two autopolymerizing acrylic resins and one heat-polymerizing acrylic resin.en
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.identifier.doi10.1016/S0022-3913(98)70008-3-
dc.identifier.wosWOS:000076548400008-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofThe Journal of prosthetic dentistry-
dc.identifier.scopus2-s2.0-0032184967-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.