dc.description.abstractSTATEMENT OF PROBLEM: Difficulties in sterilizing impressions by traditional methods have led to chemical disinfection as an alternative, and some studies have shown that disinfectants may adversely affect impressions. PURPOSE: This study investigated the effect of disinfection methods on the dimensional stability of 6 elastomeric materials. MATERIAL AND METHODS: Impression materials were submitted to the following treatments: immersion in 5.25% sodium hypochlorite solution for 10 minutes, immersion in 2% glutaraldehyde solution for 30 minutes, and no immersion (control). After treatments, impressions were poured, and respective stone casts were measured with a Nikon Profile projector and compared with the master model. RESULTS: The elastomeric materials had different reproduction capacities, and the disinfecting treatments did not differ from the control.en
dc.format.extent621-624-
dc.language.isoeng-
dc.sourceScopus-
dc.subjectbiomedical and dental materials-
dc.subjectcalcium sulfate-
dc.subjectdisinfectant agent-
dc.subjectether derivative-
dc.subjectglutaraldehyde-
dc.subjecthypochlorite sodium-
dc.subjectpolysulfide-
dc.subjectrubber-
dc.subjectsilastic-
dc.subjectsulfide-
dc.subjectchemistry-
dc.subjectcomparative study-
dc.subjectdental care-
dc.subjectdenture-
dc.subjectimmersion-
dc.subjectinstrument sterilization-
dc.subjectmaterials testing-
dc.subjectsurface property-
dc.subjectCalcium Sulfate-
dc.subjectDental Casting Technique-
dc.subjectDental Impression Materials-
dc.subjectDental Models-
dc.subjectDisinfectants-
dc.subjectEthers-
dc.subjectGlutaral-
dc.subjectImmersion-
dc.subjectMaterials Testing-
dc.subjectRubber-
dc.subjectSilicone Elastomers-
dc.subjectSodium Hypochlorite-
dc.subjectSterilization-
dc.subjectSulfides-
dc.subjectSurface Properties-
dc.subjectTime Factors-
dc.titleEffect of disinfectant agents on dimensional stability of elastomeric impression materials.en
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.identifier.doi10.1016/S0022-3913(99)70219-2-
dc.identifier.wosWOS:000080487200020-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofThe Journal of prosthetic dentistry-
dc.identifier.scopus2-s2.0-0033124328-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.