Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/65765
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Adabo, Gelson Luis | - |
dc.contributor.author | Zanarotti, E. | - |
dc.contributor.author | Fonseca, Renata Garcia | - |
dc.contributor.author | Cruz, C. A. | - |
dc.date.accessioned | 2014-05-27T11:19:43Z | - |
dc.date.accessioned | 2016-10-25T18:15:42Z | - |
dc.date.available | 2014-05-27T11:19:43Z | - |
dc.date.available | 2016-10-25T18:15:42Z | - |
dc.date.issued | 1999-05-01 | - |
dc.identifier | http://dx.doi.org/10.1016/S0022-3913(99)70219-2 | - |
dc.identifier.citation | The Journal of prosthetic dentistry, v. 81, n. 5, p. 621-624, 1999. | - |
dc.identifier.issn | 0022-3913 | - |
dc.identifier.uri | http://hdl.handle.net/11449/65765 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/65765 | - |
dc.description.abstract | STATEMENT OF PROBLEM: Difficulties in sterilizing impressions by traditional methods have led to chemical disinfection as an alternative, and some studies have shown that disinfectants may adversely affect impressions. PURPOSE: This study investigated the effect of disinfection methods on the dimensional stability of 6 elastomeric materials. MATERIAL AND METHODS: Impression materials were submitted to the following treatments: immersion in 5.25% sodium hypochlorite solution for 10 minutes, immersion in 2% glutaraldehyde solution for 30 minutes, and no immersion (control). After treatments, impressions were poured, and respective stone casts were measured with a Nikon Profile projector and compared with the master model. RESULTS: The elastomeric materials had different reproduction capacities, and the disinfecting treatments did not differ from the control. | en |
dc.format.extent | 621-624 | - |
dc.language.iso | eng | - |
dc.source | Scopus | - |
dc.subject | biomedical and dental materials | - |
dc.subject | calcium sulfate | - |
dc.subject | disinfectant agent | - |
dc.subject | ether derivative | - |
dc.subject | glutaraldehyde | - |
dc.subject | hypochlorite sodium | - |
dc.subject | polysulfide | - |
dc.subject | rubber | - |
dc.subject | silastic | - |
dc.subject | sulfide | - |
dc.subject | chemistry | - |
dc.subject | comparative study | - |
dc.subject | dental care | - |
dc.subject | denture | - |
dc.subject | immersion | - |
dc.subject | instrument sterilization | - |
dc.subject | materials testing | - |
dc.subject | surface property | - |
dc.subject | Calcium Sulfate | - |
dc.subject | Dental Casting Technique | - |
dc.subject | Dental Impression Materials | - |
dc.subject | Dental Models | - |
dc.subject | Disinfectants | - |
dc.subject | Ethers | - |
dc.subject | Glutaral | - |
dc.subject | Immersion | - |
dc.subject | Materials Testing | - |
dc.subject | Rubber | - |
dc.subject | Silicone Elastomers | - |
dc.subject | Sodium Hypochlorite | - |
dc.subject | Sterilization | - |
dc.subject | Sulfides | - |
dc.subject | Surface Properties | - |
dc.subject | Time Factors | - |
dc.title | Effect of disinfectant agents on dimensional stability of elastomeric impression materials. | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.identifier.doi | 10.1016/S0022-3913(99)70219-2 | - |
dc.identifier.wos | WOS:000080487200020 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | The Journal of prosthetic dentistry | - |
dc.identifier.scopus | 2-s2.0-0033124328 | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.