You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/66767
Full metadata record
DC FieldValueLanguage
dc.contributor.authorWakabayashi, Fabio Toshiaki-
dc.contributor.authorCanesin, Carlos Alberto-
dc.date.accessioned2014-05-27T11:20:23Z-
dc.date.accessioned2016-10-25T18:17:32Z-
dc.date.available2014-05-27T11:20:23Z-
dc.date.available2016-10-25T18:17:32Z-
dc.date.issued2002-01-01-
dc.identifierhttp://dx.doi.org/10.1109/APEC.2002.989355-
dc.identifier.citationConference Proceedings - IEEE Applied Power Electronics Conference and Exposition - APEC, v. 2, p. 924-930.-
dc.identifier.urihttp://hdl.handle.net/11449/66767-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/66767-
dc.description.abstractThis paper presents a high efficiency Sepic rectifier for an electronic ballast application with multiple fluorescent lamps. The proposed Sepic rectifier is based on a Zero-Current-Switching (ZCS) Pulse-Width-Modulated (PWM) soft-commutation cell. The high power-factor of this structure is obtained using the instantaneous average-current control technique, in order to attend properly IEC61000-3-2 standards. The inverting stage of this new electronic ballast is a classical Zero-Voltage-Switching (ZVS) Half-Bridge inverter. A proper design methodology is developed for this new electronic ballast, and a design example is presented for an application with five fluorescent lamps 40W-T12 (200W output power), 220Vrms input voltage, 130Vdc dc link voltage, with rectifier and inverter stages operating at 50kHz. Experimental results are also presented. The THD at input current is equal to 6.41%, for an input voltage THD equal to 2.14%, and the measured overall efficiency is about 92.8%, at rated load.en
dc.format.extent924-930-
dc.language.isoeng-
dc.sourceScopus-
dc.subjectElectric current control-
dc.subjectElectric inverters-
dc.subjectElectric rectifiers-
dc.subjectElectronic equipment-
dc.subjectFluorescent lamps-
dc.subjectPulse width modulation-
dc.subjectSwitching-
dc.subjectElectronic ballasts-
dc.subjectBallasts (lamp)-
dc.titleA high efficiency HPF-ZCS-PWM Sepic for electronic ballast with multiple tubular fluorescent lampsen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationPaulista State University UNESP - FEIS - DEE Power Electronics Laboratory, P.O. Box 31, 15385-000 Ilha Solteira (SP)-
dc.description.affiliationUnespPaulista State University UNESP - FEIS - DEE Power Electronics Laboratory, P.O. Box 31, 15385-000 Ilha Solteira (SP)-
dc.identifier.doi10.1109/APEC.2002.989355-
dc.identifier.wosWOS:000177210600133-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofConference Proceedings - IEEE Applied Power Electronics Conference and Exposition - APEC-
dc.identifier.scopus2-s2.0-0036078977-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.