You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/67525
Full metadata record
DC FieldValueLanguage
dc.contributor.authorDe Oliveira, Marcelo F.-
dc.contributor.authorSaczk, Adelir A.-
dc.contributor.authorGomes Neto, José Anchieta-
dc.contributor.authorRoldan, Paulo S.-
dc.contributor.authorStradiotto, Nelson Ramos-
dc.date.accessioned2014-05-27T11:20:58Z-
dc.date.accessioned2016-10-25T18:19:07Z-
dc.date.available2014-05-27T11:20:58Z-
dc.date.available2016-10-25T18:19:07Z-
dc.date.issued2003-12-01-
dc.identifierhttp://dx.doi.org/10.3390/s30900371-
dc.identifier.citationSensors, v. 3, n. 9, p. 371-380, 2003.-
dc.identifier.issn1424-3210-
dc.identifier.urihttp://hdl.handle.net/11449/67525-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/67525-
dc.description.abstractA flow-injection system with a glassy carbon disk electrode modified with Prussian Blue film is proposed for the determination of persulfate in commercial samples of hair bleaching boosters by amperometry. The detection was obtained by chronoamperometric technique and the sample is injected into the electrochemical cell in a wall jet configuration. Potassium chloride at concentration of 0.1 mol L-1 acted as sample carrier at a flow rate of 4.0 mL min-1 and supporting-electrolyte. For 0.025 V (vs. Ag/AgCl) applied voltage, the proposed system handles ca. 160 samples per hour (1.0 10-4 - 1.0 10-3 mol L-1 of persulfate), consuming about 200 μL sample and 11 mg KCl per determination. Typical linear correlations between electrocatalytic current and persulfate concentration was ca. 0.9998. The detection limit is 9.0 10-5 mol L-1 and the calculated amperometric sensibility 3.6 103 μA L mol -1. Relative standard deviation (n =12) of a 1.0 10-4 mol L-1 sample is about 2.2%. The method was applied to persulfate determination in commercial hair-bleaching samples and results are in agreement with those obtained by titrimetry at 95% confidence level and good recoveries (95 - 112%) of spiked samples were found. © 2003 by MDPI.en
dc.format.extent371-380-
dc.language.isoeng-
dc.sourceScopus-
dc.subjectAmperometry-
dc.subjectFlow injection analysis-
dc.subjectPersulfate-
dc.subjectPrussian Blue film-modified electrode-
dc.subjectElectrocatalytic effects-
dc.subjectPrussian blue film-modified electrode-
dc.subjectCatalysis-
dc.subjectConcentration (process)-
dc.subjectDeposition-
dc.subjectElectrochemistry-
dc.subjectGraphite-
dc.subjectPotassium compounds-
dc.subjectReaction kinetics-
dc.subjectVolumetric analysis-
dc.subjectElectrodes-
dc.titleFlow injection amperometric determination of persulfate in cosmetic products using a Prussian Blue film-modified electrodeen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationDepartameno de Quimica Analitica Universidade Estadual Paulista, PO Box 355, 14800-900, Araraquara-SP-
dc.description.affiliationUnespDepartameno de Quimica Analitica Universidade Estadual Paulista, PO Box 355, 14800-900, Araraquara-SP-
dc.identifier.doi10.3390/s30900371-
dc.identifier.wosWOS:000185623700005-
dc.rights.accessRightsAcesso aberto-
dc.identifier.file2-s2.0-18444381760.pdf-
dc.relation.ispartofSensors-
dc.identifier.scopus2-s2.0-18444381760-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.