You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/67583
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSilveira, M. M.-
dc.contributor.authorFonseca, Luiz Marcos da-
dc.date.accessioned2014-05-27T11:21:00Z-
dc.date.accessioned2016-10-25T18:19:15Z-
dc.date.available2014-05-27T11:21:00Z-
dc.date.available2016-10-25T18:19:15Z-
dc.date.issued2003-12-01-
dc.identifier.citationRevista de Ciencias Farmaceuticas, v. 24, n. 1, p. 71-78, 2003.-
dc.identifier.issn0101-3793-
dc.identifier.urihttp://hdl.handle.net/11449/67583-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/67583-
dc.description.abstractThe Abbott Cell-Dyn 3000 automated hematological analyzer prepares a histogram of platelet volume, which is measured by a technique using electrical impedance, inferring from its platelet count (PLT), mean platelet volume (MPV) and platelet distribution width (PDW). This equipment also calculates the plateletcrit (PCT). These platelet parameters may be important to evaluate platelet function, but they require standardization, because platelets swell when in contact with ethylenediaminetetra-acetic acid salts, hence an increase in blood sample storage time produces artificially increased results. To assess the effect of storage time on MPV, PLT, PDW and PCT, blood samples from 23 sickle cell anemia patients during steady state (Group I) and 50 from healthy controls (Group II) were placed in Vacutainer® tubes with dipotassium ethylenediaminetetra-acetic acid and measured over a period of 1440 minutes (24 h) at the following times: immediately after the venipuncture (time 0), 15, 30, 60, 120, 240, 360, 480 and 1440 minutes. The mean values of MPV and PCT were significantly increased (p<0.00001) along the storage time in both groups. The mean values of PLT and PDW were practically stable (p>0.05) throughout the storage time in both groups.en
dc.format.extent71-78-
dc.language.isoeng-
dc.sourceScopus-
dc.subjectBlood sample storage time-
dc.subjectEthylenediaminetetra- acetic acid-
dc.subjectMean platelet volume-
dc.subjectPlateletcrit-
dc.subjectStandardization-
dc.subjectblood analysis-
dc.subjectblood sampling-
dc.subjectblood storage-
dc.subjectcell swelling-
dc.subjectcontrolled study-
dc.subjectdiagnostic value-
dc.subjecthistogram-
dc.subjecthuman-
dc.subjecthuman cell-
dc.subjectimpedance-
dc.subjectmean platelet volume-
dc.subjectplatelet distribution width-
dc.subjectsickle cell anemia-
dc.subjectstandardization-
dc.subjectstorage time-
dc.subjectthrombocyte-
dc.subjectthrombocyte count-
dc.subjectthrombocyte preservation-
dc.subjectthrombocyte volume-
dc.subjecttime-
dc.subjectvein puncture-
dc.titleStandardization of platelet parameters determination in blood samples collected with EDTAen
dc.typeoutro-
dc.contributor.institutionUniversidade do Oeste Paulista (UNOESTE)-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationDepartamento de Analises Clinicas Faculdade de Farmacia e Bioquimica UNOESTE, Presidente Prudente - SP-
dc.description.affiliationDepartamento de Analises Clinicas Faculdade de Ciencias Farmaceuticas UNESP, Araraquara - SP-
dc.description.affiliationUnespDepartamento de Analises Clinicas Faculdade de Ciencias Farmaceuticas UNESP, Araraquara - SP-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofRevista de Ciencias Farmaceuticas-
dc.identifier.scopus2-s2.0-4644256640-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.