Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/67792
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Alcântara, Ilton L. | - |
dc.contributor.author | Roldan, Paulo S. | - |
dc.contributor.author | Castro, Gustavo R. | - |
dc.contributor.author | Moraes, Fabrício V. | - |
dc.contributor.author | Silva, Fábio A. | - |
dc.contributor.author | Padilha, Cilene C. F. | - |
dc.contributor.author | Oliveira, Jorge D. | - |
dc.contributor.author | Padilha, Pedro M. | - |
dc.date.accessioned | 2014-05-27T11:21:06Z | - |
dc.date.accessioned | 2016-10-25T18:19:43Z | - |
dc.date.available | 2014-05-27T11:21:06Z | - |
dc.date.available | 2016-10-25T18:19:43Z | - |
dc.date.issued | 2004-07-01 | - |
dc.identifier | http://dx.doi.org/10.2116/analsci.20.1029 | - |
dc.identifier.citation | Analytical Sciences, v. 20, n. 7, p. 1029-1032, 2004. | - |
dc.identifier.issn | 0910-6340 | - |
dc.identifier.uri | http://hdl.handle.net/11449/67792 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/67792 | - |
dc.description.abstract | A rapid and sensitive method was developed to determine trace levels of Cd2+ ions in an aqueous medium by flame atomic absorption spectrometry, using on-line preconcentration in a mini-column packed with 100 mg of 2-aminothiazol modified silica gel (SiAT). The Cd2+ ions were sorbed at pH 5.0. The preconcentrated Cd2+ ions were directly eluted from the column to the spectrometer's nebulizer-burner system using 100 μL of 2 mol L-1 hydrochloric acid. A retention efficiency of over 95% was achieved. The enrichment factor (calculated as the ratio of slopes of the calibration graphs) obtained with preconcentrations in a mini-column packed with SiAT (A = -1.3 × 10-3 + 1.8 × 10-3 [Cd2+]) and without preconcentrations (A = 4 × 10-5 + 3.5 × 10-3[Cd2+]), was 51 and the detection limit calculated was 0.38 μg L-1. The preconcentration procedure was applied to determine trace levels of Cd in river water samples. The optimum preconcentration conditions are discussed herein. | en |
dc.format.extent | 1029-1032 | - |
dc.language.iso | eng | - |
dc.source | Scopus | - |
dc.subject | 2 aminothiazole derivative | - |
dc.subject | cadmium | - |
dc.subject | hydrochloric acid | - |
dc.subject | river water | - |
dc.subject | silica gel | - |
dc.subject | adsorption | - |
dc.subject | aqueous solution | - |
dc.subject | atomic absorption spectrometry | - |
dc.subject | calibration | - |
dc.subject | combustion | - |
dc.subject | concentration (parameters) | - |
dc.subject | elution | - |
dc.subject | flame atomic absorption spectrometry | - |
dc.subject | nebulizer | - |
dc.subject | online system | - |
dc.subject | pH | - |
dc.subject | sensitivity and specificity | - |
dc.subject | water sampling | - |
dc.subject | Cadmium | - |
dc.subject | Calibration | - |
dc.subject | Hydrochloric Acid | - |
dc.subject | Hydrogen-Ion Concentration | - |
dc.subject | Ions | - |
dc.subject | Models, Chemical | - |
dc.subject | Silicon Dioxide | - |
dc.subject | Spectrophotometry | - |
dc.subject | Spectrophotometry, Atomic | - |
dc.subject | Spectrophotometry, Infrared | - |
dc.subject | Thiazoles | - |
dc.subject | Time Factors | - |
dc.subject | Water | - |
dc.title | Determination of cadmium in river water samples by flame AAS after on-line preconcentration in mini-column packed with 2-aminothiazole-modified silica gel | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.contributor.institution | Universidade Estadual do Maranhão (UEMA) | - |
dc.description.affiliation | Instituto de Química Departamento de Quimica Analitica UNESP, P. O. Box 355, 14800-900, Araraquara, SP | - |
dc.description.affiliation | Instituto de Biociência Departamento de Quimica e Bioquimica UNESP, P. O. Box 510, 18618-000, Botucatu, SP | - |
dc.description.affiliation | Instituto de Biociências Departamento de Fisica e Biofisica UNESP, P. O. Box 510, 18618-000, Botucatu, SP | - |
dc.description.affiliation | Universidade Estadual do Maranhao CESI, 65901-480, Imperatriz, MA | - |
dc.description.affiliationUnesp | Instituto de Química Departamento de Quimica Analitica UNESP, P. O. Box 355, 14800-900, Araraquara, SP | - |
dc.description.affiliationUnesp | Instituto de Biociência Departamento de Quimica e Bioquimica UNESP, P. O. Box 510, 18618-000, Botucatu, SP | - |
dc.description.affiliationUnesp | Instituto de Biociências Departamento de Fisica e Biofisica UNESP, P. O. Box 510, 18618-000, Botucatu, SP | - |
dc.identifier.doi | 10.2116/analsci.20.1029 | - |
dc.identifier.wos | WOS:000222697500007 | - |
dc.rights.accessRights | Acesso aberto | - |
dc.identifier.file | 2-s2.0-3542992106.pdf | - |
dc.relation.ispartof | Analytical Sciences | - |
dc.identifier.scopus | 2-s2.0-3542992106 | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.