Utilize este identificador para citar ou criar um link para este item:
http://acervodigital.unesp.br/handle/11449/67966
Registro de metadados completo
Campo DC | Valor | Idioma |
---|---|---|
dc.contributor.author | Assunção, Wirley Goncalves | - |
dc.contributor.author | Gennari Filho, Humberto | - |
dc.contributor.author | Zaniqueili, Osvaldo | - |
dc.date.accessioned | 2014-05-27T11:21:12Z | - |
dc.date.accessioned | 2016-10-25T18:20:05Z | - |
dc.date.available | 2014-05-27T11:21:12Z | - |
dc.date.available | 2016-10-25T18:20:05Z | - |
dc.date.issued | 2004-12-01 | - |
dc.identifier | http://dx.doi.org/10.1097/01.id.0000144509.58901.f7 | - |
dc.identifier.citation | Implant Dentistry, v. 13, n. 4, p. 358-366, 2004. | - |
dc.identifier.issn | 1056-6163 | - |
dc.identifier.uri | http://hdl.handle.net/11449/67966 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/67966 | - |
dc.description.abstract | The accuracy of impressions that transfer the relationship of the implant to the metal framework of the prosthesis continues to be a problem. This study was designed to evaluate the accuracy of the transfer process under variable conditions with regard to implant analog angulations, impression materials, and techniques. Replicas (n = 60) of a metal matrix (control) containing four implants at 90°, 80°, 75°, and 65° in relation to the horizontal surface were obtained by using three impression techniques: T1 - indirect technique with conical copings in closed trays; T2 - direct technique with square copings in open trays; and T3 - square copings splinted with autopolymerizing acrylic resin; and four elastomers: P-polysulfide; I-polyether; A-addition silicone; and Z-condensation silicone. The values of the implant analog annulations were assessed by a profilometer to the nearest 0.017°, then submitted to analysis of variance for comparisons at significance of 5% (P < .05). For implant analog at 90°, the material A associated with T2 and material Z with T3 behaved differently (P < .05) from all groups. At 80°, all materials behaved differently (P < .01) with T1. At 75°, when T1 was associated, materials P and A showed similar behavior, as well as materials I and Z; however, P and A were different from I and Z (P < .01). When T3 was associated, all experimental groups behaved differently among them (P < .01). At 65°, the materials P and Z behaved differently (P < .01) from the control group with T1, T2, and T3; the materials I and A behaved differently from the control group (P < .01) when T1 and T2, respectively, were associated. The more perpendicular the implant analog annulation is in relation to the horizontal surface, the more accurate the impression. The best materials were material I and A and the most satisfactory technique was technique 3. | en |
dc.format.extent | 358-366 | - |
dc.language.iso | eng | - |
dc.source | Scopus | - |
dc.subject | Dental implants | - |
dc.subject | Dental impression materials | - |
dc.subject | Prostheses | - |
dc.subject | Techniques | - |
dc.subject | acrylic acid resin | - |
dc.subject | elastomer | - |
dc.subject | polyether | - |
dc.subject | silicon | - |
dc.subject | accuracy | - |
dc.subject | controlled study | - |
dc.subject | statistical significance | - |
dc.subject | temperature | - |
dc.subject | tooth implantation | - |
dc.subject | tooth prosthesis | - |
dc.subject | Dental Casting Technique | - |
dc.subject | Dental Implantation, Endosseous | - |
dc.subject | Dental Implants | - |
dc.subject | Dental Impression Materials | - |
dc.subject | Dental Impression Technique | - |
dc.subject | Dental Models | - |
dc.subject | Dental Prosthesis Design | - |
dc.subject | Dental Prosthesis, Implant-Supported | - |
dc.subject | Prosthesis Fitting | - |
dc.subject | Reproducibility of Results | - |
dc.title | Evaluation of transfer impressions for osseointegrated implants at various angulations | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.contributor.institution | Universidade de São Paulo (USP) | - |
dc.description.affiliation | Dept. of Dent. Mat. and Prosthesis Sch. of Dent. at Araçatuba São Paulo State University, São Paulo | - |
dc.description.affiliation | Dept. of Dent. Mat. and Prosthesis Sch. of Dent. at Ribeirao Preto University of São Paulo, São Paulo | - |
dc.description.affiliation | , R. J. Bonifacio, 1193-Vila Mendonca, Aracatuba, SP, CEP 16015-050 | - |
dc.description.affiliationUnesp | Dept. of Dent. Mat. and Prosthesis Sch. of Dent. at Araçatuba São Paulo State University, São Paulo | - |
dc.identifier.doi | 10.1097/01.id.0000144509.58901.f7 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | Implant Dentistry | - |
dc.identifier.scopus | 2-s2.0-11444261183 | - |
Aparece nas coleções: | Artigos, TCCs, Teses e Dissertações da Unesp |
Não há nenhum arquivo associado com este item.
Itens do Acervo digital da UNESP são protegidos por direitos autorais reservados a menos que seja expresso o contrário.