Utilize este identificador para citar ou criar um link para este item:
http://acervodigital.unesp.br/handle/11449/6805
Registro de metadados completo
Campo DC | Valor | Idioma |
---|---|---|
dc.contributor.author | Moraes, Marli L. | - |
dc.contributor.author | Rodrigues Filho, Ubirajara P. | - |
dc.contributor.author | Oliveira, Osvaldo N. | - |
dc.contributor.author | Ferreira, Marystela | - |
dc.date.accessioned | 2014-05-20T13:22:55Z | - |
dc.date.accessioned | 2016-10-25T16:43:59Z | - |
dc.date.available | 2014-05-20T13:22:55Z | - |
dc.date.available | 2016-10-25T16:43:59Z | - |
dc.date.issued | 2007-11-01 | - |
dc.identifier | http://dx.doi.org/10.1007/s10008-007-0314-4 | - |
dc.identifier.citation | Journal of Solid State Electrochemistry. New York: Springer, v. 11, n. 11, p. 1489-1495, 2007. | - |
dc.identifier.issn | 1432-8488 | - |
dc.identifier.uri | http://hdl.handle.net/11449/6805 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/6805 | - |
dc.description.abstract | The layer-by-layer technique was exploited to immobilize the enzyme uricase onto indium tin oxide substrates coated with a layer of Prussian Blue. Uricase layers were alternated with either poly(ethylene imine) or poly(diallyidimethylammoniumchloride), and the resulting films were used as amperometric biosensors for uric acid. Biosensors with optimum perfomance had a limit of detection of 0.15 mu A mu mol 1(-1) cm(-2) with a linear response between 0.1 and 0.6 mu M of uric acid, which is sufficient for use in clinical tests. Bioactivity was preserved for weeks, and there was negligible influence from interferents, as detection was carried out at 0.0 V vs saturated calomel electrode. | en |
dc.format.extent | 1489-1495 | - |
dc.language.iso | eng | - |
dc.publisher | Springer | - |
dc.source | Web of Science | - |
dc.subject | layer-by-layer | pt |
dc.subject | amperometric biosensor | pt |
dc.subject | uricase | pt |
dc.subject | Prussian Blue | pt |
dc.title | Immobilization of uricase in layer-by-layer films used in amperometric biosensors for uric acid | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.contributor.institution | Universidade de São Paulo (USP) | - |
dc.description.affiliation | Univ Estadual Paulista, Dept Quim Fis & Biol, BR-19060900 Presidente Prudente, SP, Brazil | - |
dc.description.affiliation | Univ São Paulo, Inst Quim Sao Carlos, BR-13560970 Sao Carlos, SP, Brazil | - |
dc.description.affiliation | Univ São Paulo, Inst Fis Sao Carlos, BR-13560970 Sao Carlos, SP, Brazil | - |
dc.description.affiliationUnesp | Univ Estadual Paulista, Dept Quim Fis & Biol, BR-19060900 Presidente Prudente, SP, Brazil | - |
dc.identifier.doi | 10.1007/s10008-007-0314-4 | - |
dc.identifier.wos | WOS:000251676900005 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | Journal of Solid State Electrochemistry | - |
Aparece nas coleções: | Artigos, TCCs, Teses e Dissertações da Unesp |
Não há nenhum arquivo associado com este item.
Itens do Acervo digital da UNESP são protegidos por direitos autorais reservados a menos que seja expresso o contrário.