Você está no menu de acessibilidade

Utilize este identificador para citar ou criar um link para este item: http://acervodigital.unesp.br/handle/11449/6815
Registro de metadados completo
Campo DCValorIdioma
dc.contributor.authorGodoy, M.-
dc.contributor.authorHadler, J. C.-
dc.contributor.authorIunes, P. J.-
dc.contributor.authorMestanza, S. N.-
dc.contributor.authorOliveira, R. A.-
dc.contributor.authorOsorio, A. M.-
dc.contributor.authorPaulo, SR-
dc.date.accessioned2014-05-20T13:22:55Z-
dc.date.accessioned2016-10-25T16:44:00Z-
dc.date.available2014-05-20T13:22:55Z-
dc.date.available2016-10-25T16:44:00Z-
dc.date.issued2002-06-01-
dc.identifierhttp://dx.doi.org/10.1016/S1350-4487(02)00039-2-
dc.identifier.citationRadiation Measurements. Oxford: Pergamon-Elsevier B.V., v. 35, n. 3, p. 213-221, 2002.-
dc.identifier.issn1350-4487-
dc.identifier.urihttp://hdl.handle.net/11449/6815-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/6815-
dc.description.abstractThe influence of environmental conditions on the indoor radon daughters spatial distribution is studied both theoretically and experimentally. Simple theoretical calculations indicate that ventilation and variation in the size distribution of aerosols should play an important role influencing the spatial distribution of indoor radon decay products, but experimental results indicate that these environmental factors have little influence on the spatial distribution of radon daughters near the walls of indoor environments. We have observed that the maximum effective range of the plate-out effect varies only between I and 3 cm in typical dwellings. (C) 2002 Elsevier B.V. Ltd. All rights reserved.en
dc.format.extent213-221-
dc.language.isoeng-
dc.publisherElsevier B.V.-
dc.sourceWeb of Science-
dc.subjectradon daughterspt
dc.subjectindoor radon monitoringpt
dc.subjectCR-39pt
dc.subjectplate-out effectpt
dc.titleEffects of environrnental conditions on the radon daughters spatial distributionen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual de Campinas (UNICAMP)-
dc.contributor.institutionUniv Fed Mato Grosso-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationUniv Estadual Campinas, Inst Fis Gleb Wataghin, BR-13083970 Campinas, SP, Brazil-
dc.description.affiliationUniv Fed Mato Grosso, Dept Fis, ICET, BR-78060900 Cuiaba, MT, Brazil-
dc.description.affiliationUniv Estadual Paulista, Dept Fis Quim & Biol, BR-19060900 Presidente Prudente, SP, Brazil-
dc.description.affiliationUnespUniv Estadual Paulista, Dept Fis Quim & Biol, BR-19060900 Presidente Prudente, SP, Brazil-
dc.identifier.doi10.1016/S1350-4487(02)00039-2-
dc.identifier.wosWOS:000175800100009-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofRadiation Measurements-
Aparece nas coleções:Artigos, TCCs, Teses e Dissertações da Unesp

Não há nenhum arquivo associado com este item.
 

Itens do Acervo digital da UNESP são protegidos por direitos autorais reservados a menos que seja expresso o contrário.