Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/68230
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Cavalcanti, Bruno Neves | - |
dc.contributor.author | Serairdarian, Paulo Lsaías | - |
dc.contributor.author | Rode, Sigmar Mello | - |
dc.date.accessioned | 2014-05-27T11:21:19Z | - |
dc.date.accessioned | 2016-10-25T18:20:43Z | - |
dc.date.available | 2014-05-27T11:21:19Z | - |
dc.date.available | 2016-10-25T18:20:43Z | - |
dc.date.issued | 2005-05-01 | - |
dc.identifier | http://www.quintpub.com/journals/qi/abstract.php?iss2_id=159&article_id=1783 | - |
dc.identifier.citation | Quintessence International, v. 36, n. 5, p. 361-364, 2005. | - |
dc.identifier.issn | 0033-6572 | - |
dc.identifier.uri | http://hdl.handle.net/11449/68230 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/68230 | - |
dc.description.abstract | Objectives: This study measured the water flow commonly used in high-speed handpieces to evaluate the water flow's influence on temperature generation. Different flow speeds were evaluated between turbines that had different numbers of cooling apertures. Method and materials: Two water samples were collected from each high-speed handpiece at private practices and at the School of Dentistry at São José dos Campos. The first sample was collected at the customary flow and the second was collected with the terminal opened for maximum flow. The two samples were collected into weighed glass receptacles after 15 seconds of turbine operation. The glass receptacles were reweighed and the difference between weights was recorded to calculate the water flow in mL/min and for further statistical analysis. Results: The average water flow for 137 samples was 29.48 mL/min. The flow speeds obtained were 42.38 mL/min for turbines with one coolant aperture; 34.31 mL/min for turbines with two coolant apertures; and 30.44 mL/min for turbines with three coolant apertures. There were statistical differences between turbines with one and three coolant apertures (Tukey-Kramer multiple comparisons test with P < .05). Conclusion: Turbine handpieces with one cooling aperture distributed more water for the burs than high-speed handpieces with more than one aperture. | en |
dc.format.extent | 361-364 | - |
dc.language.iso | eng | - |
dc.source | Scopus | - |
dc.subject | High-speed cavity preparation | - |
dc.subject | High-speed equipment | - |
dc.subject | Pulp pathology | - |
dc.subject | glass | - |
dc.subject | calculation | - |
dc.subject | cooling | - |
dc.subject | dentistry | - |
dc.subject | equipment | - |
dc.subject | flow rate | - |
dc.subject | information processing | - |
dc.subject | intermethod comparison | - |
dc.subject | medical instrumentation | - |
dc.subject | reaction time | - |
dc.subject | school | - |
dc.subject | statistical analysis | - |
dc.subject | statistical significance | - |
dc.subject | tooth pulp | - |
dc.subject | velocity | - |
dc.subject | water flow | - |
dc.subject | water sampling | - |
dc.subject | water supply | - |
dc.subject | Body Temperature | - |
dc.subject | Burns | - |
dc.subject | Dental Cavity Preparation | - |
dc.subject | Dental High-Speed Equipment | - |
dc.subject | Dental Pulp | - |
dc.subject | Equipment Design | - |
dc.subject | Friction | - |
dc.subject | Heat | - |
dc.subject | Humans | - |
dc.subject | Rheology | - |
dc.subject | Statistics, Nonparametric | - |
dc.subject | Tooth Injuries | - |
dc.subject | Water | - |
dc.title | Water flow in high-speed handpieces | en |
dc.type | outro | - |
dc.contributor.institution | Ibirapuera University | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.description.affiliation | School of Dentistry Ibirapuera University, Sao Paulo, São Paulo | - |
dc.description.affiliation | School of Dentistry Ibirapuera University, São Paulo | - |
dc.description.affiliation | Dept. of Dent. Mat. and Prosthetics S. Paulo State Univ. - UNESP S. J., São Paulo | - |
dc.description.affiliation | , Avenida Cidade Jardim, 2680, São José dos Campos, SP | - |
dc.description.affiliationUnesp | Dept. of Dent. Mat. and Prosthetics S. Paulo State Univ. - UNESP S. J., São Paulo | - |
dc.identifier.wos | WOS:000229811400006 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | Quintessence International | - |
dc.identifier.scopus | 2-s2.0-17444420644 | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.