You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/68316
Full metadata record
DC FieldValueLanguage
dc.contributor.authorCamargo, J. R.-
dc.contributor.authorGodoy, E.-
dc.contributor.authorEbinuma, C. D.-
dc.date.accessioned2014-05-27T11:21:22Z-
dc.date.accessioned2016-10-25T18:20:54Z-
dc.date.available2014-05-27T11:21:22Z-
dc.date.available2016-10-25T18:20:54Z-
dc.date.issued2005-07-01-
dc.identifierhttp://dx.doi.org/10.1590/S1678-58782005000300005-
dc.identifier.citationJournal of the Brazilian Society of Mechanical Sciences and Engineering, v. 27, n. 3, p. 243-247, 2005.-
dc.identifier.issn1678-5878-
dc.identifier.urihttp://hdl.handle.net/11449/68316-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/68316-
dc.description.abstractEvaporative cooling operates using water and air as working fluids. It consists in water evaporation, through the passage of an airflow, thus decreasing the air temperature. This system has a great potential to provide thermal comfort in places where air humidity is low, being, however, less efficient where air humidity is high. A way to solve this problem is to use dehumidifiers to pre-conditioning the process air. This paper presents a system that can be used in humid climates coupling desiccant dehumidification equipment to evaporative coolers. The paper shows, initially, the main characteristics of the evaporative cooling and of the adsorption dehumidification systems. Later on the coupled systems, in which occurs a dehumidification by adsorption in a counter flow rotary heat exchanger following the evaporate cooling of the air in evaporative coolers, are analyzed. The thermodynamic equations of state are also presented. Following, this paper analyzes some operation parameters such as: reactivation temperature, R/P relationship (reactivation air flow/ process air flow) and the thermodynamic conditions of the entering air flow. The paper shows the conditions for the best operation point, with regard to thermal comfort conditions and to the energy used in the process. In addition this paper presents an application of the system in different climate characteristics of several tropical and equatorial cities. Copyright © 2005 by ABCM.en
dc.format.extent243-247-
dc.language.isoeng-
dc.sourceScopus-
dc.subjectDesiccant system-
dc.subjectEvaporative cooling-
dc.subjectThermal comfort-
dc.subjectAdsorbents-
dc.subjectAdsorption-
dc.subjectAir conditioning-
dc.subjectAtmospheric humidity-
dc.subjectCooling-
dc.subjectMass transfer-
dc.subjectPartial pressure-
dc.subjectSteam turbines-
dc.subjectThermodynamics-
dc.subjectDehumidification-
dc.subjectDesciccant cooling systems-
dc.subjectEvaporative cooling systems-
dc.titleAn evaporative and desiccant cooling system for air conditioning in humid climatesen
dc.typeoutro-
dc.contributor.institutionUniversidade de Taubaté - UNITAU-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationUniversidade de Taubaté - UNITAU Departamento de Engenharia Mecânica, Rua Daniel Danelli, s/n, Jardim Morumbi 12060-440 Taubate, SP-
dc.description.affiliationUniversidade do Estado de São Paulo - UNESP Faculdade de Engenharia de Guaratinguetá-FEG Departamento de Energia, Rua Ariberto Pereira da Cunha, 333, 12500-000 Guaratinguetá, SP-
dc.description.affiliationUnespUniversidade do Estado de São Paulo - UNESP Faculdade de Engenharia de Guaratinguetá-FEG Departamento de Energia, Rua Ariberto Pereira da Cunha, 333, 12500-000 Guaratinguetá, SP-
dc.identifier.doi10.1590/S1678-58782005000300005-
dc.identifier.scieloS1678-58782005000300005-
dc.rights.accessRightsAcesso aberto-
dc.identifier.file2-s2.0-23244463916.pdf-
dc.relation.ispartofJournal of the Brazilian Society of Mechanical Sciences and Engineering-
dc.identifier.scopus2-s2.0-23244463916-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.