Utilize este identificador para citar ou criar um link para este item:
http://acervodigital.unesp.br/handle/11449/68350
Registro de metadados completo
Campo DC | Valor | Idioma |
---|---|---|
dc.contributor.author | Santos, André L. | - |
dc.contributor.author | Takeuchi, Regina M. | - |
dc.contributor.author | Mariotti, Marcela P. | - |
dc.contributor.author | De Oliveira, Marcelo F. | - |
dc.contributor.author | Zanoni, Maria Valnice Boldrin | - |
dc.contributor.author | Stradiotto, Nelson Ramos | - |
dc.date.accessioned | 2014-05-27T11:21:23Z | - |
dc.date.accessioned | 2016-10-25T18:20:59Z | - |
dc.date.available | 2014-05-27T11:21:23Z | - |
dc.date.available | 2016-10-25T18:20:59Z | - |
dc.date.issued | 2005-08-01 | - |
dc.identifier | http://dx.doi.org/10.1016/j.farmac.2005.05.004 | - |
dc.identifier.citation | Farmaco, v. 60, n. 8, p. 671-674, 2005. | - |
dc.identifier.issn | 0014-827X | - |
dc.identifier.uri | http://hdl.handle.net/11449/68350 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/68350 | - |
dc.description.abstract | In this work, electrochemical oxidation of albendazole (ABZ) was carried out using a glassy carbon-rotating disk electrode. Development of electroanalytical methodology for ABZ quantification in pharmaceutical formulations was also proposed by using linear sweep voltammetric technique. Electrochemical oxidation is observed for ABZ at E 1/2 = 0.99:V vs. Ag/AgCl sat, when an anodic wave is observed. Kinetic parameters obtained for ABZ oxidation exhibited a standard heterogeneous rate constant for the electrodic process equal to (1.51 ± 0.07) ± 10 -5:cm:s -1, with a αn a value equal to 0.76. Limiting current dependence against ABZ concentration exhibited linearity on 5.0 ± 10 -5 to 1.0 ± 10 -2:mol:l -1 range, being obtained a detection limit of 2.4 ± 10 -5:mol:l -1. Proposed methodology was applied to ABZ quantification in pharmaceutical formulations. © 2005 Elsevier SAS. All rights reserved. | en |
dc.format.extent | 671-674 | - |
dc.language.iso | eng | - |
dc.source | Scopus | - |
dc.subject | Albendazole | - |
dc.subject | Glassy carbon | - |
dc.subject | Rotating disk electrode | - |
dc.subject | Voltammetric determination | - |
dc.subject | albendazole | - |
dc.subject | carbon | - |
dc.subject | silver chloride | - |
dc.subject | drug formulation | - |
dc.subject | electrochemical analysis | - |
dc.subject | electrode | - |
dc.subject | kinetics | - |
dc.subject | methodology | - |
dc.subject | oxidation | - |
dc.subject | potentiometry | - |
dc.subject | Carbon | - |
dc.subject | Electrochemistry | - |
dc.subject | Electrodes | - |
dc.subject | Glass | - |
dc.subject | Oxidation-Reduction | - |
dc.subject | Pharmaceutical Preparations | - |
dc.subject | Rotation | - |
dc.title | Study of electrochemical oxidation and determination of albendazole using a glassy carbon-rotating disk electrode | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.description.affiliation | Departamento de Química Analítica Instituto de Química UNESP, Av. Prof. Francisco Degni s/n, CEP 14800-900, Araraquara, SP | - |
dc.description.affiliationUnesp | Departamento de Química Analítica Instituto de Química UNESP, Av. Prof. Francisco Degni s/n, CEP 14800-900, Araraquara, SP | - |
dc.identifier.doi | 10.1016/j.farmac.2005.05.004 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | Farmaco | - |
dc.identifier.scopus | 2-s2.0-23944490176 | - |
dc.identifier.orcid | 0000-0002-2296-1393 | - |
Aparece nas coleções: | Artigos, TCCs, Teses e Dissertações da Unesp |
Não há nenhum arquivo associado com este item.
Itens do Acervo digital da UNESP são protegidos por direitos autorais reservados a menos que seja expresso o contrário.