You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/68728
Full metadata record
DC FieldValueLanguage
dc.contributor.authorBriso, André Luiz Fraga-
dc.contributor.authorFedel, Tânia Maria-
dc.contributor.authorPereira, Sibéria de Morais-
dc.contributor.authorMauro, Silvio José-
dc.contributor.authorSundfeld, Renato Herman-
dc.contributor.authorSundefeld, Maria Lúcia Marçal Mazza-
dc.date.accessioned2014-05-27T11:21:47Z-
dc.date.accessioned2016-10-25T18:21:50Z-
dc.date.available2014-05-27T11:21:47Z-
dc.date.available2016-10-25T18:21:50Z-
dc.date.issued2006-01-01-
dc.identifierhttp://dx.doi.org/10.1590/S1678-77572006000100003-
dc.identifier.citationJournal of Applied Oral Science, v. 14, n. 1, p. 10-15, 2006.-
dc.identifier.issn1678-7757-
dc.identifier.issn1678-7765-
dc.identifier.urihttp://hdl.handle.net/11449/68728-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/68728-
dc.description.abstractIntroduction: The evolution of light curing units can be noticed by the different systems recently introduced. The technology of LED units promises longer lifetime, without heating and with production of specific light for activation of camphorquinone. However, further studies are still required to check the real curing effectiveness of these units. Purpose: This study evaluated the microhardness of 4 shades (B-0.5, B-1, B-2 and B-3) of composite resin Filtek Z-250 (3M ESPE) after light curing with 4 light sources, being one halogen (Ultralux - Dabi Atlante) and three LED (Ultraled - Dabi Atlante, Ultrablue - DMC and Elipar Freelight - 3M ESPE). Methods: 192 specimens were distributed into 16 groups, and materials were inserted in a single increment in cylindrical templates measuring 4mm x 4mm and light cured as recommended by the manufacturer. Then, they were submitted to microhardness test on the top and bottom aspects of the cylinders. Results: The hardness values achieved were submitted to analysis of variance and to Tukey test at 5% confidence level. It was observed that microhardness of specimens varied according to the shade of the material and light sources employed. The LED appliance emitting greater light intensity provided the highest hardness values with shade B-0.5, allowing the best curing. On the other hand, appliances with low light intensity were the least effective. It was also observed that the bottom of specimens was more sensitive to changes in shade. Conclusion: Light intensity of LED light curing units is fundamental for their good functioning, especially when applied in resins with darker shades.en
dc.format.extent10-15-
dc.language.isoeng-
dc.sourceScopus-
dc.subjectComposite resins-
dc.subjectCuring equipment-
dc.subjectMicrohardness-
dc.subjectShades-
dc.titleInfluence of light curing source on microhardness of composite resins of different shadesen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationDepartment of Restorative Dentistry of Araçatuba Dental School State University of São Paulo UNESP, Araçatuba-
dc.description.affiliationAraçatuba Dental School UNESP-
dc.description.affiliationDepartment of Restorative Dentistry UNESP, R. José Bonifácio 1193, Cep.: 16015 050, Aracatuba, SP-
dc.description.affiliationUnespDepartment of Restorative Dentistry of Araçatuba Dental School State University of São Paulo UNESP, Araçatuba-
dc.description.affiliationUnespAraçatuba Dental School UNESP-
dc.description.affiliationUnespDepartment of Restorative Dentistry UNESP, R. José Bonifácio 1193, Cep.: 16015 050, Aracatuba, SP-
dc.identifier.doi10.1590/S1678-77572006000100003-
dc.identifier.scieloS1678-77572006000100003-
dc.rights.accessRightsAcesso aberto-
dc.identifier.file2-s2.0-33645872130.pdf-
dc.relation.ispartofJournal of Applied Oral Science-
dc.identifier.scopus2-s2.0-33645872130-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.