You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/68762
Full metadata record
DC FieldValueLanguage
dc.contributor.authorDias da Silva, S. R.-
dc.contributor.authorGonçalves, Mauro-
dc.date.accessioned2014-05-27T11:21:48Z-
dc.date.accessioned2016-10-25T18:21:54Z-
dc.date.available2014-05-27T11:21:48Z-
dc.date.available2016-10-25T18:21:54Z-
dc.date.issued2006-01-01-
dc.identifier.citationElectromyography and Clinical Neurophysiology, v. 46, n. 1, p. 35-42, 2006.-
dc.identifier.issn0301-150X-
dc.identifier.urihttp://hdl.handle.net/11449/68762-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/68762-
dc.description.abstractThe objective of this study was to analyze the electromyographic (EMG) signal behavior of rectus femoris (RF), vastus medialis (VM), vastus lateralis (VL) and biceps femoris (caput longum) (BFCL) from nine women during fatiguing dynamic and isometric knee extensions tests and to determine their EMGFT (Electromyographic Fatigue Threshold). Surface electrodes, biological signal acquisition module, analogical-digital converter board and specific software were used. The RMS (Root Mean Square) values obtained from concentric phase (80 to 30 degrees) of the dynamic knee extension andfrom isometric contraction were correlated with time on each load by linear regression analysis. The respective slopes were correlated with the correspondent load to determine the EMGFT. Force (Kgf) and median frequency - MF (Hz) obtained during MIVC (Maximal Isometric Voluntary Contraction) performed before and after the fatiguing tests were calculated in Matlab environment. The results demonstrated that the endurance time decreases with higher loads the EMG amplitude increase with time and was greater at higher loads, between muscles in dynamic exercise the RF and VL showed higher slopes, and in isometric exercise the VL showed the same behavior The EMGFT values were similar in both exercises; the force values predominantly decreased after fatiguing tests; however the MF only decreased after some loads. The protocols proposed allowed standardizing protocols at least to induce the fatigue process and to determine the EMGFT as an endurance indicative, which may be used to evaluate the effectiveness of rehabilitative or training interventions indicated to reduce muscle weakness and fatigue.en
dc.format.extent35-42-
dc.language.isoeng-
dc.sourceScopus-
dc.subjectDynamic contraction-
dc.subjectElectromyography-
dc.subjectIsometric contraction-
dc.subjectKnee-
dc.subjectMuscle fatigue-
dc.subjectadult-
dc.subjectanalog digital converter-
dc.subjectbiceps femoris muscle-
dc.subjectcalculation-
dc.subjectclinical protocol-
dc.subjectcomputer program-
dc.subjectcontrolled study-
dc.subjectcorrelation analysis-
dc.subjectdisplay system-
dc.subjectdynamic exercise-
dc.subjectdynamics-
dc.subjectelectrode-
dc.subjectelectromyogram-
dc.subjectendurance-
dc.subjectfemale-
dc.subjecthuman-
dc.subjecthuman experiment-
dc.subjectknee-
dc.subjectleg movement-
dc.subjectleg muscle-
dc.subjectmuscle fatigue-
dc.subjectmuscle force-
dc.subjectmuscle isometric contraction-
dc.subjectmuscle training-
dc.subjectmuscle weakness-
dc.subjectnormal human-
dc.subjectrectus femoris muscle-
dc.subjectrehabilitation-
dc.subjectsignal processor-
dc.subjectstandardization-
dc.subjectstatistical analysis-
dc.subjectvastus lateralis muscle-
dc.subjectweight bearing-
dc.subjectAdolescent-
dc.subjectAdult-
dc.subjectFemale-
dc.subjectHumans-
dc.subjectMuscle Contraction-
dc.subjectMuscle Fatigue-
dc.subjectQuadriceps Muscle-
dc.subjectReference Values-
dc.subjectWeight-Bearing-
dc.titleDynamic and isometric protocols of knee extension: Effect of fatigue on the EMG signalen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationBiomechanic Laboratory São Paulo State University UNESP, Avenida 24A n 1515 - Bela Vista, Rio Claro, São Paulo-
dc.description.affiliationUnespBiomechanic Laboratory São Paulo State University UNESP, Avenida 24A n 1515 - Bela Vista, Rio Claro, São Paulo-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofElectromyography and Clinical Neurophysiology-
dc.identifier.scopus2-s2.0-33644982615-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.