You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/69031
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSantini, Alberto O.-
dc.contributor.authorOliveira, Jose Eduardo de-
dc.contributor.authorPezza, Helena Redigolo-
dc.contributor.authorPezza, Leonardo-
dc.date.accessioned2014-05-27T11:21:56Z-
dc.date.accessioned2016-10-25T18:22:32Z-
dc.date.available2014-05-27T11:21:56Z-
dc.date.available2016-10-25T18:22:32Z-
dc.date.issued2006-08-09-
dc.identifierhttp://dx.doi.org/10.1590/S0103-50532006000400022-
dc.identifier.citationJournal of the Brazilian Chemical Society, v. 17, n. 4, p. 785-791, 2006.-
dc.identifier.issn0103-5053-
dc.identifier.urihttp://hdl.handle.net/11449/69031-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/69031-
dc.description.abstractThe characteristics, performance, and application of an electrode, namely, Pt|Hg|Hg 2(NAP) 2| Graphite, where NAP stands for naproxenate ion, are described. This electrode responds to NAP with sensivity of (58.1± 0.9) mV decade -1 over the range 5.0 × 10 -5 - 1.0 × 10 -2 mol L -1 at pH 6.0-9.0 and a detection limit of 3.9 × 10 -5 mol L -1. The electrode is easily constructed at a relatively low cost with fast response time (within 10-35 s) and can be used for a period of 6 months without any considerable divergence in potentials. The proposed sensor displayed good selectivity for naproxen in the presence of several substances, especially concerning carboxylate and inorganic anions. It was used for the direct assay of naproxen in commercial tablets by means of the standard additions method. The analytical results obtained by using this electrode are in good agreement with those given by the United States Pharmacopeia procedure. ©2006 Sociedade Brasileira de Química.en
dc.format.extent785-791-
dc.language.isoeng-
dc.sourceScopus-
dc.subjectNaproxenate-sensitive electrode-
dc.subjectPharmaceutical formulations-
dc.subjectPotentiometry-
dc.titleA novel potentiometric naproxenate ion sensor immobilized in a graphite matrix for determination of naproxen in pharmaceuticalsen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationInstituto de Química Universidade Estadual Paulista, CP 355, 14801-970 Araraquara-SP-
dc.description.affiliationUnespInstituto de Química Universidade Estadual Paulista, CP 355, 14801-970 Araraquara-SP-
dc.identifier.doi10.1590/S0103-50532006000400022-
dc.identifier.scieloS0103-50532006000400022-
dc.identifier.wosWOS:000239616800021-
dc.rights.accessRightsAcesso aberto-
dc.identifier.file2-s2.0-33746754680.pdf-
dc.relation.ispartofJournal of the Brazilian Chemical Society-
dc.identifier.scopus2-s2.0-33746754680-
dc.identifier.orcid0000-0003-0197-7369pt
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.