You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/69541
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPavan, Sabrina-
dc.contributor.authorArioli Filho, João Neudenir-
dc.contributor.authorSantos, Paulo Henrique dos-
dc.contributor.authorNogueira, Sergio Sualdini-
dc.contributor.authorBatista, André Ulisses Dantas-
dc.date.accessioned2014-05-27T11:22:25Z-
dc.date.accessioned2016-10-25T18:23:36Z-
dc.date.available2014-05-27T11:22:25Z-
dc.date.available2016-10-25T18:23:36Z-
dc.date.issued2007-03-01-
dc.identifierhttp://dx.doi.org/10.1111/j.1532-849X.2007.00162.x-
dc.identifier.citationJournal of Prosthodontics, v. 16, n. 2, p. 101-106, 2007.-
dc.identifier.issn1059-941X-
dc.identifier.issn1532-849X-
dc.identifier.urihttp://hdl.handle.net/11449/69541-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/69541-
dc.description.abstractPurpose: To evaluate the effects of disinfection treatments with chemical solutions (2% glutaraldehyde, 5% sodium hypochlorite, and 5% chlorhexidine) and microwave energy on the hardness of four long-term soft denture liners. Materials and Methods: Forty rectangular specimens of four soft lining materials (Molloplast-B, Ufi Gel P, Eversoft, and Mucopren soft) were made for each material. Ten samples of each material were immersed in different disinfectant solutions for 10 minutes or placed in a microwave oven for 3 minutes at 500 W. The hardness values were obtained with a Shore A durometer, before the first disinfection cycle (control), and also after two cycles of disinfection. Data were submitted to analysis of variance and Tukey's test (p < 0.01). Results: The highest value of hardness was obtained for Molloplast-B, independent of the disinfection technique. Mucopren soft demonstrated intermediate values and Ufi Gel P and Eversoft the lowest values of Shore A hardness. For Molloplast-B, the disinfection using glutaraldehyde demonstrated the highest value of hardness. The number of disinfections had no effect on the hardness values for all the materials studied and disinfection techniques. Conclusions: The application of two disinfection cycles did not change the Shore A hardness values for all the materials. The glutaraldehyde solution demonstrated the highest values of Shore A hardness for the Molloplast-B, Mucopren soft, and Ufi Gel P materials, while Eversoft did not present any differences in hardness when submitted to different disinfection treatments. Copyright © 2007 by The American College of Prosthodontists.en
dc.format.extent101-106-
dc.language.isoeng-
dc.sourceScopus-
dc.subjectDisinfection-
dc.subjectHardness-
dc.subjectSoft liner material-
dc.subjectdenture-
dc.subjectdisinfection-
dc.subjectdrug effect-
dc.subjecthardness-
dc.subjectmicrowave radiation-
dc.subjectradiation exposure-
dc.subjectDenture Liners-
dc.subjectMicrowaves-
dc.titleEffect of disinfection treatments on the hardness of soft denture liner materialsen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionFederal University of Paraíba-
dc.description.affiliationDepartment of Dental Materials and Prosthodontics Araraquara Dental School São Paulo State University, Araraquara, São Paulo-
dc.description.affiliationDepartment of Dental Materials and Prosthodontics Araçatuba Dental School São Paulo State University, Araçatuba, São Paulo-
dc.description.affiliationDepartment of Restorative Dentistry Federal University of Paraíba, João Pessoa, Paraíba-
dc.description.affiliation, R. Presidente Bernardes, 482 ap. 144, Araçatuba, SP 6015-353-
dc.description.affiliationUnespDepartment of Dental Materials and Prosthodontics Araraquara Dental School São Paulo State University, Araraquara, São Paulo-
dc.description.affiliationUnespDepartment of Dental Materials and Prosthodontics Araçatuba Dental School São Paulo State University, Araçatuba, São Paulo-
dc.identifier.doi10.1111/j.1532-849X.2007.00162.x-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofJournal of Prosthodontics-
dc.identifier.scopus2-s2.0-33947238827-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.