Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/69541
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Pavan, Sabrina | - |
dc.contributor.author | Arioli Filho, João Neudenir | - |
dc.contributor.author | Santos, Paulo Henrique dos | - |
dc.contributor.author | Nogueira, Sergio Sualdini | - |
dc.contributor.author | Batista, André Ulisses Dantas | - |
dc.date.accessioned | 2014-05-27T11:22:25Z | - |
dc.date.accessioned | 2016-10-25T18:23:36Z | - |
dc.date.available | 2014-05-27T11:22:25Z | - |
dc.date.available | 2016-10-25T18:23:36Z | - |
dc.date.issued | 2007-03-01 | - |
dc.identifier | http://dx.doi.org/10.1111/j.1532-849X.2007.00162.x | - |
dc.identifier.citation | Journal of Prosthodontics, v. 16, n. 2, p. 101-106, 2007. | - |
dc.identifier.issn | 1059-941X | - |
dc.identifier.issn | 1532-849X | - |
dc.identifier.uri | http://hdl.handle.net/11449/69541 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/69541 | - |
dc.description.abstract | Purpose: To evaluate the effects of disinfection treatments with chemical solutions (2% glutaraldehyde, 5% sodium hypochlorite, and 5% chlorhexidine) and microwave energy on the hardness of four long-term soft denture liners. Materials and Methods: Forty rectangular specimens of four soft lining materials (Molloplast-B, Ufi Gel P, Eversoft, and Mucopren soft) were made for each material. Ten samples of each material were immersed in different disinfectant solutions for 10 minutes or placed in a microwave oven for 3 minutes at 500 W. The hardness values were obtained with a Shore A durometer, before the first disinfection cycle (control), and also after two cycles of disinfection. Data were submitted to analysis of variance and Tukey's test (p < 0.01). Results: The highest value of hardness was obtained for Molloplast-B, independent of the disinfection technique. Mucopren soft demonstrated intermediate values and Ufi Gel P and Eversoft the lowest values of Shore A hardness. For Molloplast-B, the disinfection using glutaraldehyde demonstrated the highest value of hardness. The number of disinfections had no effect on the hardness values for all the materials studied and disinfection techniques. Conclusions: The application of two disinfection cycles did not change the Shore A hardness values for all the materials. The glutaraldehyde solution demonstrated the highest values of Shore A hardness for the Molloplast-B, Mucopren soft, and Ufi Gel P materials, while Eversoft did not present any differences in hardness when submitted to different disinfection treatments. Copyright © 2007 by The American College of Prosthodontists. | en |
dc.format.extent | 101-106 | - |
dc.language.iso | eng | - |
dc.source | Scopus | - |
dc.subject | Disinfection | - |
dc.subject | Hardness | - |
dc.subject | Soft liner material | - |
dc.subject | denture | - |
dc.subject | disinfection | - |
dc.subject | drug effect | - |
dc.subject | hardness | - |
dc.subject | microwave radiation | - |
dc.subject | radiation exposure | - |
dc.subject | Denture Liners | - |
dc.subject | Microwaves | - |
dc.title | Effect of disinfection treatments on the hardness of soft denture liner materials | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.contributor.institution | Federal University of Paraíba | - |
dc.description.affiliation | Department of Dental Materials and Prosthodontics Araraquara Dental School São Paulo State University, Araraquara, São Paulo | - |
dc.description.affiliation | Department of Dental Materials and Prosthodontics Araçatuba Dental School São Paulo State University, Araçatuba, São Paulo | - |
dc.description.affiliation | Department of Restorative Dentistry Federal University of Paraíba, João Pessoa, Paraíba | - |
dc.description.affiliation | , R. Presidente Bernardes, 482 ap. 144, Araçatuba, SP 6015-353 | - |
dc.description.affiliationUnesp | Department of Dental Materials and Prosthodontics Araraquara Dental School São Paulo State University, Araraquara, São Paulo | - |
dc.description.affiliationUnesp | Department of Dental Materials and Prosthodontics Araçatuba Dental School São Paulo State University, Araçatuba, São Paulo | - |
dc.identifier.doi | 10.1111/j.1532-849X.2007.00162.x | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | Journal of Prosthodontics | - |
dc.identifier.scopus | 2-s2.0-33947238827 | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.