Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/69881
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Weinert, Patrícia L. | - |
dc.contributor.author | Pezza, Leonardo | - |
dc.contributor.author | Pezza, Helena Redigolo | - |
dc.date.accessioned | 2014-05-27T11:22:35Z | - |
dc.date.accessioned | 2016-10-25T18:24:18Z | - |
dc.date.available | 2014-05-27T11:22:35Z | - |
dc.date.available | 2016-10-25T18:24:18Z | - |
dc.date.issued | 2007-09-06 | - |
dc.identifier | http://dx.doi.org/10.1590/S0103-50532007000400026 | - |
dc.identifier.citation | Journal of the Brazilian Chemical Society, v. 18, n. 4, p. 846-854, 2007. | - |
dc.identifier.issn | 0103-5053 | - |
dc.identifier.issn | 1678-4790 | - |
dc.identifier.uri | http://hdl.handle.net/11449/69881 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/69881 | - |
dc.description.abstract | This paper describes a simple, portable and environmentally friendly method for the rapid determination of dipyrone in pharmaceuticals by using diffuse reflectance spectroscopy. The proposed method is based on the reflectance measurements of the orange compound produced from the spot test reaction between dipyrone and p-dimethylaminocinnamaldehyde (p-DAC), in acid medium, using a filter paper as solid support. Experimental design methodologies were used to optimize the measurement conditions. All reflectance measurements were carried out at 510 nm and the linear range was from 1.42 × 10-4-2.85 × 10-3 mol L-1, with a correlation coefficient of 0.999. The limit of detection (LOD) and the limit of quantification (LOQ) were 1.20 × 10-5 mol L-1 and 4.00 × 10-5 mol L-1, respectively. The intraday precision and interday precision were studied for 10 replicate analyses of 7.90 × 10-4 mol L-1 dipyrone solution. The coefficients of variation were 1.1 and 0.9%, respectively. The proposed method was applied successfully to the determination of dipyrone in commercial brands of pharmaceuticals. No interferences were observed from the common excipients in formulations. The results obtained by the proposed method were favorably compared with those given by the Brazilian Pharmacopoeia procedure at 95% confidence level. ©2007 Sociedade Brasileira de Química. | en |
dc.format.extent | 846-854 | - |
dc.language.iso | eng | - |
dc.source | Scopus | - |
dc.subject | Dipyrone | - |
dc.subject | Pharmaceutical formulations | - |
dc.subject | Reflectance spectroscopy | - |
dc.subject | Spot test | - |
dc.title | A simplified reflectometric method for the rapid determination of dipyrone in pharmaceutical formulations | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.description.affiliation | Instituto de Química Universidade Estadual Paulista, CP 355, 14801-970 Araraquara-SP | - |
dc.description.affiliationUnesp | Instituto de Química Universidade Estadual Paulista, CP 355, 14801-970 Araraquara-SP | - |
dc.identifier.doi | 10.1590/S0103-50532007000400026 | - |
dc.identifier.scielo | S0103-50532007000400026 | - |
dc.identifier.wos | WOS:000249204300026 | - |
dc.rights.accessRights | Acesso aberto | - |
dc.identifier.file | 2-s2.0-34548296994.pdf | - |
dc.relation.ispartof | Journal of the Brazilian Chemical Society | - |
dc.identifier.scopus | 2-s2.0-34548296994 | - |
dc.identifier.orcid | 0000-0003-0197-7369 | pt |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.