Você está no menu de acessibilidade

Utilize este identificador para citar ou criar um link para este item: http://acervodigital.unesp.br/handle/11449/70217
Título: 
Critical parameter determination of sonic flow controller diamond microtubes and micronozzles
Autor(es): 
Instituição: 
  • Universidade de São Paulo (USP)
  • Universidade Estadual Paulista (UNESP)
ISSN: 
1071-1023
Resumo: 
In this article, the authors measure throughput of sonic diamond microtubes and micronozzles that can work as passive gas flow controllers and flow meters under choking conditions. The behavior of the outlet pressure through the microdevices using an experimental setup with constant volume and constant temperature was determined in order to obtain the critical throughput, the critical mass flow rate, and the discharge coefficients of the diamond sonic microdevices. © 2007 American Vacuum Society.
Data de publicação: 
19-Dez-2007
Citação: 
Journal of Vacuum Science and Technology B: Microelectronics and Nanometer Structures, v. 25, n. 6, p. 1804-1807, 2007.
Duração: 
1804-1807
Palavras-chaves: 
  • Diamonds
  • Flow rate
  • Flowmeters
  • Throughput
  • Discharge coefficients
  • Microdevices
  • Micronozzles
  • Microtubes
  • Sonic flow
  • Flow control
Fonte: 
http://dx.doi.org/10.1116/1.2790924
Endereço permanente: 
Direitos de acesso: 
Acesso restrito
Tipo: 
outro
Fonte completa:
http://repositorio.unesp.br/handle/11449/70217
Aparece nas coleções:Artigos, TCCs, Teses e Dissertações da Unesp

Não há nenhum arquivo associado com este item.
 

Itens do Acervo digital da UNESP são protegidos por direitos autorais reservados a menos que seja expresso o contrário.