You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/70225
Full metadata record
DC FieldValueLanguage
dc.contributor.authorJosgrilberg, Érika Botelho-
dc.contributor.authorGuimarães, Murilo de Sousa-
dc.contributor.authorPansani, Cyneu Aguiar-
dc.contributor.authorCordeiro, Rita de Cássia Loiola-
dc.date.accessioned2014-05-27T11:22:45Z-
dc.date.accessioned2016-10-25T18:25:05Z-
dc.date.available2014-05-27T11:22:45Z-
dc.date.available2016-10-25T18:25:05Z-
dc.date.issued2007-12-31-
dc.identifierhttp://dx.doi.org/10.1590/S1806-83242007000400014-
dc.identifier.citationBrazilian Oral Research, v. 21, n. 4, p. 362-367, 2007.-
dc.identifier.issn1806-8324-
dc.identifier.issn1807-3107-
dc.identifier.urihttp://hdl.handle.net/11449/70225-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/70225-
dc.description.abstractThe aim of this study was to evaluate the shape of dental cavities made with the CVDentus® system using different ultrasound power levels. One standard cavity was made on the buccal aspect of 15 bovine incisors with a CVDentus® cylindrical bur (82142). The sample was divided into three groups: G1 - ultrasound with power II; G2 - ultrasound with power III; and G3 - ultrasound with power IV. A standardizing device was used to obtain standardized preparations and ultrasound was applied during one minute in each dental preparation. The cavities were sectioned in the middle, allowing observation of the cavity's profile with a magnifying glass, and width and depth measurement using the Leica Qwin program. The Kruskal-Wallis (p < 0.05) and Dunn statistical analyses demonstrated differences between the dental cavity shapes when powers III and IV were used. However, the cavities that were made with power III presented dimensions similar to those of the bur used for preparation. We concluded that the power recommended by the manufacturer (III) is the most adequate for use with the CVDentus® system.en
dc.format.extent362-367-
dc.language.isoeng-
dc.sourceScopus-
dc.subjectDental cavity preparation-
dc.subjectDiamond-
dc.subjectTechnology, dental-
dc.subjectUltrasonography-
dc.subjectdiamond-
dc.subjectanimal-
dc.subjectcattle-
dc.subjectclinical trial-
dc.subjectcontrolled clinical trial-
dc.subjectcontrolled study-
dc.subjectdental surgery-
dc.subjectechography-
dc.subjectequipment design-
dc.subjectinstrumentation-
dc.subjectmethodology-
dc.subjectnonparametric test-
dc.subjectrandomized controlled trial-
dc.subjectsurface property-
dc.subjecttooth pulp-
dc.subjectultrasound therapy-
dc.subjectAnimals-
dc.subjectCattle-
dc.subjectDental Cavity Preparation-
dc.subjectDental Pulp Cavity-
dc.subjectEquipment Design-
dc.subjectStatistics, Nonparametric-
dc.subjectSurface Properties-
dc.subjectUltrasonic Therapy-
dc.titleInfluence of the power level of an ultra-sonic system on dental cavity preparationen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationDepartment of Pediatrics School of Dentistry of Araraquara São Paulo State University, São Paulo-
dc.description.affiliationDepartamento de Clínica Infantil, R. Humaitá 1680, Araraquara, SP 14801-903-
dc.description.affiliationUnespDepartment of Pediatrics School of Dentistry of Araraquara São Paulo State University, São Paulo-
dc.identifier.doi10.1590/S1806-83242007000400014-
dc.identifier.scieloS1806-83242007000400014-
dc.rights.accessRightsAcesso aberto-
dc.identifier.file2-s2.0-37349090111.pdf-
dc.relation.ispartofBrazilian Oral Research-
dc.identifier.scopus2-s2.0-37349090111-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.