You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/7054
Full metadata record
DC FieldValueLanguage
dc.contributor.authorVanderlei, L. C. M.-
dc.contributor.authorSilva, R. A.-
dc.contributor.authorPastre, C. M.-
dc.contributor.authorAzevedo, Fábio Mícolis de-
dc.contributor.authorGodoy, M. F.-
dc.date.accessioned2014-05-20T13:23:24Z-
dc.date.available2014-05-20T13:23:24Z-
dc.date.issued2008-10-01-
dc.identifierhttp://dx.doi.org/10.1590/S0100-879X2008005000039-
dc.identifier.citationBrazilian Journal of Medical and Biological Research. Associação Brasileira de Divulgação Científica, v. 41, n. 10, p. 854-859, 2008.-
dc.identifier.issn0100-879X-
dc.identifier.urihttp://hdl.handle.net/11449/7054-
dc.description.abstractThe aim of the present study was to compare heart rate variability (HRV) at rest and during exercise using a temporal series obtained with the Polar S810i monitor and a signal from a LYNX® signal conditioner (BIO EMG 1000 model) with a channel configured for the acquisition of ECG signals. Fifteen healthy subjects aged 20.9 ± 1.4 years were analyzed. The subjects remained at rest for 20 min and performed exercise for another 20 min with the workload selected to achieve 60% of submaximal heart rate. RR series were obtained for each individual with a Polar S810i instrument and with an ECG analyzed with a biological signal conditioner. The HRV indices (rMSSD, pNN50, LFnu, HFnu, and LF/HF) were calculated after signal processing and analysis. The unpaired Student t-test and intraclass correlation coefficient were used for data analysis. No statistically significant differences were observed when comparing the values analyzed by means of the two devices for HRV at rest and during exercise. The intraclass correlation coefficient demonstrated satisfactory correlation between the values obtained by the devices at rest (pNN50 = 0.994; rMSSD = 0.995; LFnu = 0.978; HFnu = 0.978; LF/HF = 0.982) and during exercise (pNN50 = 0.869; rMSSD = 0.929; LFnu = 0.973; HFnu = 0.973; LF/HF = 0.942). The calculation of HRV values by means of temporal series obtained from the Polar S810i instrument appears to be as reliable as those obtained by processing the ECG signal captured with a signal conditioner.en
dc.description.sponsorshipFundação para o Desenvolvimento da UNESP (FUNDUNESP)-
dc.format.extent854-859-
dc.language.isoeng-
dc.publisherAssociação Brasileira de Divulgação Científica (ABRADIC)-
dc.sourceSciELO-
dc.subjectHeart rate variabilityen
dc.subjectAutonomic nervous systemen
dc.subjectExerciseen
dc.subjectSpectral analysisen
dc.subjectECGen
dc.subjectPolar S810i monitoren
dc.titleComparison of the Polar S810i monitor and the ECG for the analysis of heart rate variability in the time and frequency domainsen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionFaculdade de Medicina de São José do Rio Preto (FAMERP)-
dc.description.affiliationUniversidade Estadual Paulista Departamento de Fisioterapia-
dc.description.affiliationUniversidade Estadual Paulista Curso de Especialização em Fisioterapia-
dc.description.affiliationUniversidade Estadual Paulista Faculdade de Ciências e Tecnologia Laboratório de Fisioterapia Aplicada ao Movimento Humano-
dc.description.affiliationFaculdade de Medicina de São José do Rio Preto (FAMERP) Departamento de Cardiologia e Cirurgia Cardiovascular-
dc.description.affiliationUnespUniversidade Estadual Paulista Departamento de Fisioterapia-
dc.description.affiliationUnespUniversidade Estadual Paulista Curso de Especialização em Fisioterapia-
dc.description.affiliationUnespUniversidade Estadual Paulista Faculdade de Ciências e Tecnologia Laboratório de Fisioterapia Aplicada ao Movimento Humano-
dc.description.sponsorshipIdFUNDUNESP: 00931/08-DFP-
dc.identifier.doi10.1590/S0100-879X2008005000039-
dc.identifier.scieloS0100-879X2008001000004-
dc.identifier.wosWOS:000261171400004-
dc.rights.accessRightsAcesso aberto-
dc.identifier.fileS0100-879X2008001000004.pdf-
dc.relation.ispartofBrazilian Journal of Medical and Biological Research-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.