You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/70580
Full metadata record
DC FieldValueLanguage
dc.contributor.authorCanesin, C. A.-
dc.contributor.authorGonçalves, F. A S-
dc.contributor.authorLeandro, E.-
dc.contributor.authorPinto, J. O P-
dc.date.accessioned2014-05-27T11:23:40Z-
dc.date.accessioned2016-10-25T18:26:01Z-
dc.date.available2014-05-27T11:23:40Z-
dc.date.available2016-10-25T18:26:01Z-
dc.date.issued2008-09-22-
dc.identifierhttp://dx.doi.org/10.1109/SPEEDHAM.2008.4581246-
dc.identifier.citationSPEEDAM 2008 - International Symposium on Power Electronics, Electrical Drives, Automation and Motion, p. 848-853.-
dc.identifier.urihttp://hdl.handle.net/11449/70580-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/70580-
dc.description.abstractThis paper is based on the analysis and implementation of a new drive system applied to refrigeration systems, complying with the restrictions imposed by the IEC standards (Harmonic/Flicker/EMI-Electromagnetic Interference restrictions), in order to obtain high efficiency, high power factor, reduced harmonic distortion in the input current and reduced electromagnetic interference, with excellent performance in temperature control of a refrigeration prototype system (automatic control, precision and high dynamic response). The proposal is replace the single-phase motor by a three-phase motor, in the conventional refrigeration system. In this way, a proper control technique can be applied, using a closed-loop (feedback control), that will allow an accurate adjustment of the desirable temperature. The proposed refrigeration prototype uses a 0.5Hp three-phase motor and an open (Belt-Drive) Bitzer IY type compressor. The input rectifier stage's features include the reduction in the input current ripple, the reduction in the output voltage ripple, the use of low stress devices, low volume for the EMI input filter, high input power factor (PF), and low total harmonic distortion (THD) in the input current, in compliance with the IEC61000-3-2 standards. The digital controller for the output three-phase inverter stage has been developed using a conventional voltage-frequency control (scalar V/f control), and a simplified stator oriented Vector control, in order to verify the feasibility and performance of the proposed digital controls for continuous temperature control applied at the refrigerator prototype. ©2008 IEEE.en
dc.format.extent848-853-
dc.language.isoeng-
dc.sourceScopus-
dc.subjectHPF rectifier-
dc.subjectPower quality-
dc.subjectVariable speed refrigeration system-
dc.subjectAutomation-
dc.subjectCapillary tubes-
dc.subjectConcurrency control-
dc.subjectControl system analysis-
dc.subjectControl systems-
dc.subjectControl theory-
dc.subjectDigital arithmetic-
dc.subjectDigital control systems-
dc.subjectDrives-
dc.subjectDynamic response-
dc.subjectElectric power factor-
dc.subjectElectric power factor correction-
dc.subjectElectromagnetic compatibility-
dc.subjectElectromagnetic pulse-
dc.subjectElectromagnetic wave interference-
dc.subjectElectromagnetism-
dc.subjectHarmonic distortion-
dc.subjectInduction motors-
dc.subjectIndustrial engineering-
dc.subjectInformation theory-
dc.subjectMotors-
dc.subjectPower electronics-
dc.subjectRefrigerating machinery-
dc.subjectRefrigeration-
dc.subjectRefrigerators-
dc.subjectRegulatory compliance-
dc.subjectSignal interference-
dc.subjectStages-
dc.subjectStandards-
dc.subjectTemperature control-
dc.subjectWave filters-
dc.subjectAutomatic control-
dc.subjectClosed loops-
dc.subjectControl techniques-
dc.subjectDigital controllers-
dc.subjectDigital controls-
dc.subjectDrive systems-
dc.subjectElectrical drives-
dc.subjectElectro magnetic interferences-
dc.subjectExcellent performance-
dc.subjectFrequency controls-
dc.subjectHigh input power-
dc.subjectHigh power factors-
dc.subjectHigh-efficiency-
dc.subjectIEC standards-
dc.subjectInput current ripple-
dc.subjectInput currents-
dc.subjectInternational symposium-
dc.subjectLow-stress-
dc.subjectOutput voltage ripple-
dc.subjectPhase motors-
dc.subjectPrototype systems-
dc.subjectRefrigeration systems-
dc.subjectTemperature controlling-
dc.subjectThree-phase inverters-
dc.subjectThree-phase motors-
dc.subjectTotal Harmonic Distortion-
dc.subjectV/F control-
dc.subjectVariable speed-
dc.subjectVector controls-
dc.subjectElectric rectifiers-
dc.titleVariable speed refrigeration system with HPF input rectifier stageen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionUniversidade Federal de Mato Grosso do Sul (UFMS)-
dc.description.affiliationSão Paulo State University UNESP FEIS, 15385-000 Ilha Solteira, SP-
dc.description.affiliationFederal University of Mato Grosso do Sul UFMS, 79070-900 Campo Grande, MS-
dc.description.affiliationUnespSão Paulo State University UNESP FEIS, 15385-000 Ilha Solteira, SP-
dc.identifier.doi10.1109/SPEEDHAM.2008.4581246-
dc.identifier.wosWOS:000259920400152-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofSPEEDAM 2008 - International Symposium on Power Electronics, Electrical Drives, Automation and Motion-
dc.identifier.scopus2-s2.0-51849130709-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.