Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/70590
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Zambra, D. A B | - |
dc.contributor.author | Rech, C. | - |
dc.contributor.author | Gonçalves, F. A S | - |
dc.contributor.author | Pinheiro, J. R. | - |
dc.date.accessioned | 2014-05-27T11:23:40Z | - |
dc.date.accessioned | 2016-10-25T18:26:02Z | - |
dc.date.available | 2014-05-27T11:23:40Z | - |
dc.date.available | 2016-10-25T18:26:02Z | - |
dc.date.issued | 2008-09-29 | - |
dc.identifier | http://dx.doi.org/10.1109/PESC.2008.4592632 | - |
dc.identifier.citation | PESC Record - IEEE Annual Power Electronics Specialists Conference, p. 4290-4295. | - |
dc.identifier.issn | 0275-9306 | - |
dc.identifier.uri | http://hdl.handle.net/11449/70590 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/70590 | - |
dc.description.abstract | This paper presents the comparison of three topologies of multilevel inverters applied to drive an induction motor of 500 kVA/4.16 kV. The multilevel inverters analyzed are: a neutral point clamped inverter, a symmetrical cascaded multilevel inverter and a hybrid asymmetrical cascaded multilevel inverter. The performance indexes used in the comparison are total harmonic distortion, first order distortion factor, semiconductors power losses distribution and heat-sink volume. The comparison is developed with the purpose of finding the efficiency and the heat-sink volume where the three systems present the same output filter. ©2008 IEEE. | en |
dc.format.extent | 4290-4295 | - |
dc.language.iso | eng | - |
dc.source | Scopus | - |
dc.subject | Cooling | - |
dc.subject | Electric inverters | - |
dc.subject | Induction motors | - |
dc.subject | Land vehicle propulsion | - |
dc.subject | Topology | - |
dc.subject | Wave filters | - |
dc.subject | Cascaded multilevel inverters | - |
dc.subject | Cooling system design | - |
dc.subject | First orders | - |
dc.subject | Multi-level inverters | - |
dc.subject | Neutral point clamped inverters | - |
dc.subject | Output filtering | - |
dc.subject | Performance indexes | - |
dc.subject | Power losses | - |
dc.subject | Total Harmonic Distortion | - |
dc.subject | Power electronics | - |
dc.title | Power losses analysis and cooling system design of three topologies of multilevel inverters | en |
dc.type | outro | - |
dc.contributor.institution | Power Electronics and Control Research Group | - |
dc.contributor.institution | Santa Catarina State University | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.description.affiliation | Federal University of Santa Maria Power Electronics and Control Research Group, Santa Maria | - |
dc.description.affiliation | Santa Catarina State University Department of Electrical Engineering, Joinville | - |
dc.description.affiliation | São Paulo State University Department of Electrical Engineering, Ilha Solteira | - |
dc.description.affiliationUnesp | São Paulo State University Department of Electrical Engineering, Ilha Solteira | - |
dc.identifier.doi | 10.1109/PESC.2008.4592632 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | PESC Record - IEEE Annual Power Electronics Specialists Conference | - |
dc.identifier.scopus | 2-s2.0-52349088455 | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.