You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/70629
Full metadata record
DC FieldValueLanguage
dc.contributor.authorKuriki, Heloyse Uliam-
dc.contributor.authorde Azevedo, F. Mícolis-
dc.contributor.authorde Faria Negrão Filho, R.-
dc.contributor.authorAlves, Neri-
dc.contributor.authorde Carvalho, Augusto Cesinando-
dc.date.accessioned2014-05-27T11:23:41Z-
dc.date.accessioned2016-10-25T18:26:07Z-
dc.date.available2014-05-27T11:23:41Z-
dc.date.available2016-10-25T18:26:07Z-
dc.date.issued2008-11-01-
dc.identifier.citationElectromyography and Clinical Neurophysiology, v. 48, n. 8, p. 367-372, 2008.-
dc.identifier.issn0301-150X-
dc.identifier.urihttp://hdl.handle.net/11449/70629-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/70629-
dc.description.abstractIt was purposed the use of electromyography (EMG) to evaluate the activation of the agonists and antagonists muscles of spastic patients, to test the viability in the development of an instrument that given quantitative data of the patient spasticity. 30 hemiplegic and 15 normal volunteers had been submitted to the EMG of flexor and extensor carpi ulnaris muscles during the flexion and extension movements of the wrist. The individuals with less severe spasticity (mAS (modified Ashworth Scale) ringing 0 to 3 degree), had presented deficit in the activation of the flexor muscles in plegic side in relation to the non plegic side and that the individuals seriously compromised by the spasticity (mAS = 4 degree) present deficit of reciprocal inhibition. One evidenced is that the non plegic member does not present a similar neuro-motor comportment when compared to the normal member. The surface electromyography is a practical clinical instrument to evaluate the patient with spasticity and the hemiplegic patient needs to be evaluated on both sides (deficient and no deficient) because the no compromised side do not show a normality standard.en
dc.format.extent367-372-
dc.language.isoeng-
dc.sourceScopus-
dc.subjectAgonist-antagonist relationship-
dc.subjectHemiplegia-
dc.subjectSpasticity-
dc.subjectSurface electromyography-
dc.subjectadult-
dc.subjectclinical article-
dc.subjectclinical effectiveness-
dc.subjectcomparative study-
dc.subjectcontrolled study-
dc.subjectdisease severity-
dc.subjectelectromyography-
dc.subjectevidence based practice-
dc.subjectfemale-
dc.subjectflexor muscle-
dc.subjectforearm-
dc.subjecthemiplegia-
dc.subjecthuman-
dc.subjectjoint limitation-
dc.subjectmale-
dc.subjectmotoneuron-
dc.subjectquantitative analysis-
dc.subjectrating scale-
dc.subjectspasticity-
dc.subjectwrist-
dc.subjectAged-
dc.subjectElectromyography-
dc.subjectFemale-
dc.subjectForearm-
dc.subjectHumans-
dc.subjectMale-
dc.subjectMiddle Aged-
dc.subjectMovement-
dc.subjectMuscle Contraction-
dc.subjectMuscle Spasticity-
dc.subjectMuscle, Skeletal-
dc.titleComparative analysis of electromyographic pattern in the forearm muscles of hemiplegic patientsen
dc.typeoutro-
dc.contributor.institutionUniversidade de São Paulo (USP)-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationPost-Graduation Program Interunits in Bioengineering São Carlos Engineering School São Paulo University, Tomogiro Othiai, St. 216. Jd. Bongiovani, 19050-360 Presidente Prudente, SP-
dc.description.affiliationHuman Movement Applied Physiotherapy Laboratory of Science and Technology College São Paulo State University, Roberto Simonsen, St. 305, 19060-900 Presidente Prudente, SP-
dc.description.affiliationUnespHuman Movement Applied Physiotherapy Laboratory of Science and Technology College São Paulo State University, Roberto Simonsen, St. 305, 19060-900 Presidente Prudente, SP-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofElectromyography and Clinical Neurophysiology-
dc.identifier.scopus2-s2.0-57049133039-
dc.identifier.orcid0000-0001-8001-301Xpt
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.