You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/70871
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMarafão, Fernando Pinhabel-
dc.contributor.authorColón, D.-
dc.contributor.authorJardini, J. A.-
dc.contributor.authorKomatsu, W.-
dc.contributor.authorMatakas, L.-
dc.contributor.authorGalassi, M.-
dc.contributor.authorAhn, S. U.-
dc.contributor.authorBormio, E.-
dc.contributor.authorCamargo, J. C.-
dc.contributor.authorMonteiro, T.-
dc.contributor.authorOliveira, M. A.-
dc.date.accessioned2014-05-27T11:23:50Z-
dc.date.accessioned2016-10-25T18:26:43Z-
dc.date.available2014-05-27T11:23:50Z-
dc.date.available2016-10-25T18:26:43Z-
dc.date.issued2008-12-23-
dc.identifierhttp://dx.doi.org/10.1109/ICHQP.2008.4668857-
dc.identifier.citation2008 13th International Conference on Harmonics and Quality of Power, Vols 1 and 2. New York: IEEE, p. 669-674, 2008.-
dc.identifier.urihttp://hdl.handle.net/11449/70871-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/70871-
dc.description.abstractThis paper deals with the design and analysis of a Dynamic Voltage Restorer output voltage control. Such control is based on a multiloop strategy, with an inner current PID regulator and an outer P+Resonant voltage controller. The inner regulator is applied on the output inductor current. It will be also demonstrated how the load current behavior may influence in the DVR output voltage, which justifies the need for the resonant controller. Additionally, it will be discussed the application of a modified algorithm for the identification of the DVR voltage references, which is based on a previously presented positive sequence detector. Since the studied three-phase DVR is assumed to be based on three identical H-bridge converters, all the analysis and design procedures were realized by means of single-phase equivalent circuits. The discussions and conclusions are supported by theoretical calculations, nonlinear simulations and some experimental results. ©2008 IEEE.en
dc.language.isoeng-
dc.sourceScopus-
dc.subjectDynamic voltage restorer-
dc.subjectFeedback control systems-
dc.subjectPositive sequence-
dc.subjectPower electronics converters-
dc.subjectResonant controller-
dc.subjectAdaptive control systems-
dc.subjectControl systems-
dc.subjectElectric potential-
dc.subjectEquivalent circuits-
dc.subjectFeedback-
dc.subjectFeedback control-
dc.subjectIdentification (control systems)-
dc.subjectPower electronics-
dc.subjectPower quality-
dc.subjectTurbulent flow-
dc.subjectVideodisks-
dc.subjectVoltage control-
dc.subjectVoltage regulators-
dc.subjectAnalysis and designs-
dc.subjectDesign and analyses-
dc.subjectH bridges-
dc.subjectLoad currents-
dc.subjectModified algorithms-
dc.subjectMultiloop controllers-
dc.subjectNonlinear simulations-
dc.subjectOutput inductors-
dc.subjectOutput voltages-
dc.subjectPid regulators-
dc.subjectReference generators-
dc.subjectTheoretical calculations-
dc.subjectVoltage controllers-
dc.subjectVoltage references-
dc.subjectElectric control equipment-
dc.titleMultiloop controller and reference generator for a dynamic voltage restorer implementationen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionUniversidade de São Paulo (USP)-
dc.contributor.institutionCompanhia Paulista de Forca e Luz-
dc.contributor.institutionExpertise Engenharia-
dc.description.affiliationGroup of Automation and Integrating Systems Paulista State University, Sorocaba, SP-
dc.description.affiliationEscola Politécnica São Paulo University, Sao Paulo, SP-
dc.description.affiliationCompanhia Paulista de Forca e Luz, Campinas, SP-
dc.description.affiliationExpertise Engenharia, Campinas, SP-
dc.description.affiliationUnespGroup of Automation and Integrating Systems Paulista State University, Sorocaba, SP-
dc.identifier.doi10.1109/ICHQP.2008.4668857-
dc.identifier.wosWOS:000262985500115-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofICHQP 2008: 13th International Conference on Harmonics and Quality of Power-
dc.identifier.scopus2-s2.0-57749101093-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.