You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/71250
Full metadata record
DC FieldValueLanguage
dc.contributor.authorDe Oliveira Jr., José Martins-
dc.contributor.authorMartins, Antonio César Germano-
dc.date.accessioned2014-05-27T11:24:02Z-
dc.date.accessioned2016-10-25T18:27:39Z-
dc.date.available2014-05-27T11:24:02Z-
dc.date.available2016-10-25T18:27:39Z-
dc.date.issued2009-11-27-
dc.identifierhttp://dx.doi.org/10.1063/1.3157786-
dc.identifier.citationAIP Conference Proceedings, v. 1139, p. 102-105.-
dc.identifier.issn0094-243X-
dc.identifier.issn1551-7616-
dc.identifier.urihttp://hdl.handle.net/11449/71250-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/71250-
dc.description.abstractX-ray computed tomography (CT) refers to the cross-sectional imaging of an object measuring the transmitted radiation at different directions. In this work, we describe the development of a low cost micro-CT X-ray scanner that is being developed for nondestructive testing. This tomograph operates using a microfocus X-ray source and contains a silicon photodiode as detectors. The performance of the system, by its spatial resolution, has been estimated through its Modulation Transfer Function - MTF and the obtained value at 10% of MTF is 661 μm. It was built as a general purpose nondestructive testing device. © 2009 American Institute of Physics.en
dc.format.extent102-105-
dc.language.isoeng-
dc.sourceScopus-
dc.subjectImage analysis-
dc.subjectNondestructive inspections-
dc.subjectTomography-
dc.subjectX-ray-
dc.titleConstruction and test of low cost X-ray tomography scanner for physical-chemical analysis and nondestructive inspectionsen
dc.typeoutro-
dc.contributor.institutionUniversidade de Sorocaba - UNISO-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationUniversidade de Sorocaba - UNISO Campus Seminário, Caixa Postal 578, Av. Dr. Eugênio Salermo, 100, Centro, 18035-430, Sorocaba, SP-
dc.description.affiliationUniversidade Estadual Paulista Julio de Mesquita Filho - UNESP GASI Alto da Boa Vista, Av. 3 de Março, 511, 18087-180, Sorocaba, SP-
dc.description.affiliationUnespUniversidade Estadual Paulista Julio de Mesquita Filho - UNESP GASI Alto da Boa Vista, Av. 3 de Março, 511, 18087-180, Sorocaba, SP-
dc.identifier.doi10.1063/1.3157786-
dc.rights.accessRightsAcesso restrito-
dc.identifier.file2-s2.0-70450214020.pdf-
dc.relation.ispartofAIP Conference Proceedings-
dc.identifier.scopus2-s2.0-70450214020-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.