You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/71267
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPontes, Wesley-
dc.contributor.authorDe Carvalho, Aparecido Augusto-
dc.contributor.authorSanches, Marcelo Augusto Assunção-
dc.contributor.authorDe Freitas, Ricardo Luiz Barros-
dc.contributor.authorDe Paula, Mauro Henrique-
dc.contributor.authorSakamoto, Walter Katsumi-
dc.date.accessioned2014-05-27T11:24:03Z-
dc.date.accessioned2016-10-25T18:27:42Z-
dc.date.available2014-05-27T11:24:03Z-
dc.date.available2016-10-25T18:27:42Z-
dc.date.issued2009-12-01-
dc.identifierhttp://dx.doi.org/10.1007/978-3-642-03902-7-192-
dc.identifier.citationIFMBE Proceedings, v. 25, n. 3, p. 667-670, 2009.-
dc.identifier.issn1680-0737-
dc.identifier.urihttp://hdl.handle.net/11449/71267-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/71267-
dc.description.abstractA microcontrolled instrument for measuring the energy fluence rate (or intensity) of X-ray pulses in the orthovoltage range of 120 to 300 kV is described. The prototype instrument consists of a pyroelectric sensor, a low-noise highsensitivity current-to-voltage converter, a microcontroller and a digital display. The response of the instrument is nonlinear with the intensity of the radiation. The precision is better than 3%. The equipment is inexpensive, rugged, simple to construct and has good long-term stability. © 2009 Springer-Verlag.en
dc.format.extent667-670-
dc.language.isoeng-
dc.sourceScopus-
dc.subjectEnergy fluence rate-
dc.subjectMicrocontrolled instrument-
dc.subjectOrthovoltage range-
dc.subjectPyroelectric sensor-
dc.subjectX-ray intensity-
dc.subjectEnergy fluences-
dc.subjectOrthovoltage-
dc.subjectPyroelectric sensors-
dc.subjectX ray intensity-
dc.subjectBiomedical engineering-
dc.subjectDosimetry-
dc.subjectInstruments-
dc.subjectLithium-
dc.subjectNiobium compounds-
dc.subjectPhysics-
dc.subjectRadiation shielding-
dc.subjectSensors-
dc.subjectX rays-
dc.subjectBiological radiation effects-
dc.titleMeasurement of orthovoltage X-ray intensity with a lithium niobate transduceren
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionFederal University of Mato Grosso Do Sul-
dc.description.affiliationDepartment of Electrical Engineering São Paulo State University - UNESP, Avenida Brasil, 56, Ilha Solteira-
dc.description.affiliationPhysics Department Federal University of Mato Grosso Do Sul, Campo Grande, MS 79070-900-
dc.description.affiliationDepto. Physics and Chemistry São Paulo State University - UNESP, Ilha Solteira, SP 15385-000-
dc.description.affiliationUnespDepartment of Electrical Engineering São Paulo State University - UNESP, Avenida Brasil, 56, Ilha Solteira-
dc.description.affiliationUnespDepto. Physics and Chemistry São Paulo State University - UNESP, Ilha Solteira, SP 15385-000-
dc.identifier.doi10.1007/978-3-642-03902-7-192-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofIFMBE Proceedings-
dc.identifier.scopus2-s2.0-77950124310-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.