Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/71332
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | de Chaves, Carolina Andrade Lima | - |
dc.contributor.author | Regis, Rômulo Rocha | - |
dc.contributor.author | Machado, Ana Lucia | - |
dc.contributor.author | de Souza, Raphael Freitas | - |
dc.date.accessioned | 2014-05-27T11:24:04Z | - |
dc.date.accessioned | 2016-10-25T18:27:49Z | - |
dc.date.available | 2014-05-27T11:24:04Z | - |
dc.date.available | 2016-10-25T18:27:49Z | - |
dc.date.issued | 2009-12-01 | - |
dc.identifier | http://dx.doi.org/10.1590/S0103-64402009000200007 | - |
dc.identifier.citation | Brazilian Dental Journal, v. 20, n. 2, p. 127-131, 2009. | - |
dc.identifier.issn | 0103-6440 | - |
dc.identifier.issn | 1806-4760 | - |
dc.identifier.uri | http://hdl.handle.net/11449/71332 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/71332 | - |
dc.description.abstract | This study evaluated the effect of denture base polymer type (heat- and microwave-polymerized), ridge lap surface treatment (with and without methyl methacrylate-MMA etching) and thermocycling on the microtensile bond strength (mTBS) of Biotone acrylic teeth. Flat-ground, ridge-lap surface of posterior artifcial teeth were bonded to cylinders of each denture base resin, resulting in the following groups (n=6): G1a - Clássico/with MMA etching; G1b - Clássico/without MMA etching; G2a - OndaCryl/with MMA etching; G2b - OndaCryl/without MMA etching. Rectangular bar specimens with a cross-sectional area of 1 mm 2 were prepared. Half of the bars in each group were thermocycled (5,000 cycles between 4°C and 60°C). mTBS testing was performed in an universal testing machine at a crosshead speed of 0.5 mm/min. Data were analyzed statistically by three-way ANOVA (a=0.05). There was no statisti-caly signifcant difference (p>0.05) for the factors (resin, surface treatment,and thermocycling) or their interactions. The mean mTBS values (MPa) and standard deviations were as follows: Thermocycling - G1a: 41.00 (14.00); G1b: 31.00 (17.00); G2a: 50.00 (27.00); G2b: 40.00 (18.00); No thermocycling - G1a: 37.00 (14.00); G1b: 43.00 (25.00); G2a: 43.00 (14.00); G2b: 40.00 (27.00). The mTBS of Biotone artifcial teeth to the denture base acrylic resins was not infuenced by the polymer type, surface treatment or thermocycling. | en |
dc.format.extent | 127-131 | - |
dc.language.iso | eng | - |
dc.source | Scopus | - |
dc.subject | Acrylic resins | - |
dc.subject | Artifcial tooth | - |
dc.subject | Microtensile bond strength | - |
dc.subject | Surface treatment | - |
dc.title | Effect of ridge lap surface treatment and thermocycling on microtensile bond strength of acrylic teeth to denture base resins | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.contributor.institution | Universidade de São Paulo (USP) | - |
dc.description.affiliation | Department of Dental Materials and Prosthodontics, Araraquara Dental School São Paulo State University, Araraquara, SP | - |
dc.description.affiliation | Department of Dental Materials and Prosthodontics Ribeirão Preto Dental School University of São Paulo, Ribeirão Preto, SP | - |
dc.description.affiliationUnesp | Department of Dental Materials and Prosthodontics, Araraquara Dental School São Paulo State University, Araraquara, SP | - |
dc.identifier.doi | 10.1590/S0103-64402009000200007 | - |
dc.identifier.scielo | S0103-64402009000200007 | - |
dc.rights.accessRights | Acesso aberto | - |
dc.identifier.file | 2-s2.0-70449727199.pdf | - |
dc.relation.ispartof | Brazilian Dental Journal | - |
dc.identifier.scopus | 2-s2.0-70449727199 | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.