Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/71508
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Saade, E. G. | - |
dc.contributor.author | Bandéca, M. C. | - |
dc.contributor.author | Saade, J. L. | - |
dc.contributor.author | Rossato, D. M. | - |
dc.contributor.author | Rastelli, Alessandra Nara de Souza | - |
dc.contributor.author | Bagnato, V. S. | - |
dc.contributor.author | Porto-Neto, S. T. | - |
dc.date.accessioned | 2014-05-27T11:24:35Z | - |
dc.date.accessioned | 2016-10-25T18:28:13Z | - |
dc.date.available | 2014-05-27T11:24:35Z | - |
dc.date.available | 2016-10-25T18:28:13Z | - |
dc.date.issued | 2010-01-01 | - |
dc.identifier | http://dx.doi.org/10.1134/S1054660X10010172 | - |
dc.identifier.citation | Laser Physics, v. 20, n. 1, p. 285-290, 2010. | - |
dc.identifier.issn | 1054-660X | - |
dc.identifier.issn | 1555-6611 | - |
dc.identifier.uri | http://hdl.handle.net/11449/71508 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/71508 | - |
dc.description.abstract | The purpose of this study was to evaluate the effect of pre-heating resin composite photo-cured with light-curing units (LCU) by FT-IR. Twenty specimens were made in a metallic mold (4 mm diameter × 2 mm thick) from composite resin-Tetric Ceram® (Ivoclar/Vivadent) at room temperature (25°C) and pre-heated to 37, 54, and 60°C. The specimens were cured with halogen curing light (QTH) and light emitted by diodes (LED) during 40 s. Then, the specimens were pulverized, pressed with KBr and analyzed with FT-IR. The data were submitted to statistical analysis of variance and Kruskal-Wallis test. Study data showed no statistically significant difference to the degree of conversion for the different light curing units (QTH and LED) (p > 0.05). With the increase of temperature there was significant increase in the degree of conversion (p < 0.05). In this study were not found evidence that the light curing unit and temperature influenced the degree of conversion. © 2010 Pleiades Publishing, Ltd. | en |
dc.format.extent | 285-290 | - |
dc.language.iso | eng | - |
dc.source | Scopus | - |
dc.subject | Composite resins | - |
dc.subject | Degree of conversion | - |
dc.subject | Halogen curing | - |
dc.subject | Kruskal | - |
dc.subject | Light-curing units | - |
dc.subject | Metallic mold | - |
dc.subject | Monomer conversions | - |
dc.subject | Resin composites | - |
dc.subject | Room temperature | - |
dc.subject | Statistical analysis | - |
dc.subject | Statistically significant difference | - |
dc.subject | Dental composites | - |
dc.subject | Heating | - |
dc.subject | Light emitting diodes | - |
dc.subject | Regression analysis | - |
dc.subject | Resins | - |
dc.subject | Curing | - |
dc.title | Effect of pre-heating resin composite and light-curing units on monomer conversion | en |
dc.type | outro | - |
dc.contributor.institution | Universidade de São Paulo (USP) | - |
dc.contributor.institution | Universidade do Sagrado Coração (USC) | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.description.affiliation | Araraquara School of Dentistry Department of Restorative Dentistry University of São Paulo State, Humaitá St., 1680, Araraquara, SP 14801-903 | - |
dc.description.affiliation | University of Sagrado Coração, 10-50 Irmã Arminda St., Bauru 17011-160 | - |
dc.description.affiliation | São Carlos Physics Institute University of São Paulo, Trabalhador São Carlense Avenue 400, São Carlos, SP 13566-970 | - |
dc.identifier.doi | 10.1134/S1054660X10010172 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | Laser Physics | - |
dc.identifier.scopus | 2-s2.0-76849098494 | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.