Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/71584
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Gandini Júnior, Luiz Gonzaga | - |
dc.contributor.author | Gandini, Márcia Regina Elisa Aparecida Schiavon | - |
dc.contributor.author | Amaral, Roberta Maria de Paula | - |
dc.date.accessioned | 2014-05-27T11:24:38Z | - |
dc.date.accessioned | 2016-10-25T18:28:23Z | - |
dc.date.available | 2014-05-27T11:24:38Z | - |
dc.date.available | 2016-10-25T18:28:23Z | - |
dc.date.issued | 2010-03-01 | - |
dc.identifier | http://dx.doi.org/10.1016/j.ajodo.2008.01.022 | - |
dc.identifier.citation | American Journal of Orthodontics and Dentofacial Orthopedics, v. 137, n. 3, p. 393-395, 2010. | - |
dc.identifier.issn | 0889-5406 | - |
dc.identifier.uri | http://hdl.handle.net/11449/71584 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/71584 | - |
dc.description.abstract | This article describes an orthodontic system used to obtain active continuous torque with movement control of both active and reactive units; the system relies on principles of the segmented technique. A cantilever system with .017 x .025-in beta-titanium alloy wire was designed to provide the desirable moment on the active unit. A transpalatal bar or a lingual arch increases the anchorage and neutralizes the side effects on the reactive unit. This technique is an efficient approach for major corrections of buccolingual inclinations of certain teeth. © 2010 American Association of Orthodontists. | en |
dc.format.extent | 393-395 | - |
dc.language.iso | eng | - |
dc.source | Scopus | - |
dc.subject | case report | - |
dc.subject | dental care | - |
dc.subject | evaluation | - |
dc.subject | human | - |
dc.subject | instrumentation | - |
dc.subject | methodology | - |
dc.subject | orthodontics | - |
dc.subject | periodontal disease | - |
dc.subject | torque | - |
dc.subject | Dental Stress Analysis | - |
dc.subject | Humans | - |
dc.subject | Orthodontic Anchorage Procedures | - |
dc.subject | Orthodontic Appliance Design | - |
dc.subject | Orthodontic Extrusion | - |
dc.subject | Tooth Movement | - |
dc.subject | Torque | - |
dc.title | Continuous torque system with control of the reaction unit | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.description.affiliation | Department of Orthodontics Araraquara Dental School University of the State of São Paulo, Araraquara, São Paulo | - |
dc.identifier.doi | 10.1016/j.ajodo.2008.01.022 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | American Journal of Orthodontics and Dentofacial Orthopedics | - |
dc.identifier.scopus | 2-s2.0-77249145354 | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.