Effects of gamma-irradiation on caprolactam level from multilayer PA-6 films for food packaging: Development and validation of a gas chromatographic method
Autor(es): 
Instituição: 
  • Universidade Estadual Paulista (UNESP)
  • Instituto de Pesquisas Energéticas e Nucleares (IPEN)
  • Food Technol Inst CETEA ITAL
ISSN: 
0969-806X
Resumo: 
A gas chromatographic method to determine caprolactam in multilayer PA-6 films used for meat foodstuffs and cheese was developed and validated. A wide linear range (0.8-400 mu g/ml), RSD <= 4.1% and recovery higher than 90.0% were obtained for the chromatographic system, while precision and accuracy of the method showed RSD <= 3.8%, recovery from 95.5-100.0% and LOQ of 32 mu g/g. Irradiated (3, 7 and 12 kGy) and non-irradiated commercial films were analyzed. Most of them increased caprolactam levels with the increase of irradiation doses. (C) 2008 Elsevier Ltd. All rights reserved.
Data de publicação: 
1-Jul-2008
Citação: 
Radiation Physics and Chemistry. Oxford: Pergamon-Elsevier B.V. Ltd, v. 77, n. 7, p. 913-917, 2008.
Duração: 
913-917
Publicador: 
Pergamon-Elsevier B.V. Ltd
Palavras-chaves: 
  • gamma-irradiation
  • caprolactam
  • food-packaging multilayer films
  • polyamide 6
  • GC
  • validation
Fonte: 
http://dx.doi.org/10.1016/j.radphyschem.2008.03.001
Endereço permanente: 
Direitos de acesso: 
Acesso restrito
Tipo: 
outro
Fonte completa:
http://repositorio.unesp.br/handle/11449/7171
Aparece nas coleções:Artigos, TCCs, Teses e Dissertações da Unesp

Não há nenhum arquivo associado com este item.
 

Itens do Acervo digital da UNESP são protegidos por direitos autorais reservados a menos que seja expresso o contrário.