Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/72254
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Da Silva, Ricardo Moutinho | - |
dc.contributor.author | Borges, Paulo Paschoal | - |
dc.contributor.author | Serta Fraga, Isabel Cristina | - |
dc.contributor.author | Stradiotto, Nelson Ramos | - |
dc.date.accessioned | 2014-05-27T11:25:26Z | - |
dc.date.accessioned | 2016-10-25T18:33:28Z | - |
dc.date.available | 2014-05-27T11:25:26Z | - |
dc.date.available | 2016-10-25T18:33:28Z | - |
dc.date.issued | 2011-01-01 | - |
dc.identifier | http://dx.doi.org/10.1520/JAI103192 | - |
dc.identifier.citation | Journal of ASTM International, v. 8, n. 1, 2011. | - |
dc.identifier.issn | 1546-962X | - |
dc.identifier.uri | http://hdl.handle.net/11449/72254 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/72254 | - |
dc.description.abstract | Studies carried out with glass electrode in anhydrous ethanol and ethanol-water solutions for measuring pH values have shown that this parameter depends on the solution composition, the contact time with the solution, the utilized temperature, and the type of electrolyte used. It was also observed that the glass electrode behavior in an acid medium differs from an alkaline medium. These studies provided correction factors for pH values from 2 to 12, allowing the realization of proper measurements of the hydrogen ionic activity in the ethanol-water and anhydrous ethanol solutions. However, these correction factors could not be applied to the fuel ethanol. Alternatively, a new method was developed for the correction of the pH values, which can be applied in hydrous and anhydrous fuel ethanol samples. Copyright © 2011 by ASTM International. | en |
dc.language.iso | eng | - |
dc.source | Scopus | - |
dc.subject | Ethanol-water solutions | - |
dc.subject | Fuel ethanol | - |
dc.subject | Glass electrode | - |
dc.subject | pH | - |
dc.subject | Acid medium | - |
dc.subject | Alkaline medium | - |
dc.subject | Anhydrous ethanol | - |
dc.subject | Contact time | - |
dc.subject | Correction factors | - |
dc.subject | Ethanol-water | - |
dc.subject | Glass electrodes | - |
dc.subject | Ionic activity | - |
dc.subject | Measuring pH | - |
dc.subject | PH measurements | - |
dc.subject | pH value | - |
dc.subject | Solution composition | - |
dc.subject | Electrodes | - |
dc.subject | Fuels | - |
dc.subject | Glass | - |
dc.subject | pH effects | - |
dc.subject | Ethanol | - |
dc.title | New methodology for pH measurements in fuel ethanol using glass electrode | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.contributor.institution | Normalização e Qualidade Industrial (INMETRO) | - |
dc.description.affiliation | Dept. of Analytical Chemistry Institute of Chemistry UNESP, Rua Francisco Degni, s/n, Bairro Quitandinha, 14800-900 Araraquara, São Paolo | - |
dc.description.affiliation | Divisão de Metrologia Química Instituto Nacional de Metrologia Normalização e Qualidade Industrial (INMETRO), CEP: 25250-020, Rio de Janeiro, Rio de Janeiro | - |
dc.description.affiliationUnesp | Dept. of Analytical Chemistry Institute of Chemistry UNESP, Rua Francisco Degni, s/n, Bairro Quitandinha, 14800-900 Araraquara, São Paolo | - |
dc.identifier.doi | 10.1520/JAI103192 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | Journal of ASTM International | - |
dc.identifier.scopus | 2-s2.0-78751674643 | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.