You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/72396
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPedrosa, Valber A.-
dc.contributor.authorYan, Jun-
dc.contributor.authorSimonian, Aleksandr L.-
dc.contributor.authorRevzin, Alexander-
dc.date.accessioned2014-05-27T11:25:51Z-
dc.date.accessioned2016-10-25T18:33:50Z-
dc.date.available2014-05-27T11:25:51Z-
dc.date.available2016-10-25T18:33:50Z-
dc.date.issued2011-05-01-
dc.identifierhttp://dx.doi.org/10.1002/elan.201000654-
dc.identifier.citationElectroanalysis, v. 23, n. 5, p. 1142-1149, 2011.-
dc.identifier.issn1040-0397-
dc.identifier.issn1521-4109-
dc.identifier.urihttp://hdl.handle.net/11449/72396-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/72396-
dc.description.abstractThis paper describes the use of Au nanoparticle (NP)-containing hydrogel microstructures in the development of electrochemical enzyme-based biosensors. To fabricate biosensors, AuNPs were conjugated with glucose oxidase (GOX) or horseradish peroxidase (HRP) molecules and were dispersed in the prepolymer solution of poly(ethylene glycol) diacrylate (PEG-DA). Vinylferrocene (VF) was also added into the prepolymer solution in order to lower operating potential of the biosensor and to prevent oxidation of interfering substances. The prepolymer solution was photolithographically patterned in alignment with an array of Au electrodes fabricated on glass. As a result, electrode arrays became functionalized with AuNP/GOX- or AuNP/HRP-carrying hydrogel microstructures. Performance of the biosensors was characterized by impedance spectroscopy, chronoapmerometry and cyclic voltammetry. Impedance measurements revealed that inclusion of Au nanoparticles improved conductivity of PEG hydrogel by a factor of 5. Importantly, biosensors based on AuNP-GOX complex exhibited high sensitivity to glucose (100μAmM -1cm -2) in the linear range from 0.1 to 10mM. The detection limit was estimated to be 3.7×10- 7M at a signal-to-noise ratio of 3. Biosensors with immobilized AuNP/HPR had a linear response from 0.5 to 5.0μM of hydrogen peroxide with sensitivity of 1.4mAmM -1cm -2. The method for fabricating nanoparticle-carrying hydrogel microstructures described in this paper should be widely applicable in the development of robust and sensitive electrochemical biosensors. © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.en
dc.format.extent1142-1149-
dc.language.isoeng-
dc.sourceScopus-
dc.subjectGlucose oxidase-
dc.subjectGold nanoparticles-
dc.subjectHPR-
dc.subjectHydrogel-
dc.titleMicropatterned nanocomposite hydrogels for biosensing applicationsen
dc.typeoutro-
dc.contributor.institutionAuburn University-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionUniversity of California-
dc.description.affiliationDepartment of Materials Engineering Auburn University, Auburn, AL 36849-
dc.description.affiliationInstitute of Bioscience Department of Chemistry and Biochemistry UNESP, Botucatu, SP-
dc.description.affiliationDepartment of Biomedical Engineering University of California, Davis, 451 Health Sciences St. #2619, Davis, CA 95616-
dc.description.affiliationUnespInstitute of Bioscience Department of Chemistry and Biochemistry UNESP, Botucatu, SP-
dc.identifier.doi10.1002/elan.201000654-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofElectroanalysis-
dc.identifier.scopus2-s2.0-79955611451-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.