dc.contributor.authorBíscaro, A. A P-
dc.contributor.authorPereira, R. A F-
dc.contributor.authorMantovani, J. R S-
dc.date.accessioned2014-05-27T11:25:53Z-
dc.date.accessioned2016-10-25T18:33:56Z-
dc.date.available2014-05-27T11:25:53Z-
dc.date.available2016-10-25T18:33:56Z-
dc.date.issued2011-05-31-
dc.identifierhttp://dx.doi.org/10.1109/TDC-LA.2010.5762858-
dc.identifier.citation2010 IEEE/PES Transmission and Distribution Conference and Exposition: Latin America, T and D-LA 2010, p. 37-43.-
dc.identifier.urihttp://hdl.handle.net/11449/72441-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/72441-
dc.description.abstractThis paper proposes a new approach for optimal phasor measurement units placement for fault location on electric power distribution systems using Greedy Randomized Adaptive Search Procedure metaheuristic and Monte Carlo simulation. The optimized placement model herein proposed is a general methodology that can be used to place devices aiming to record the voltage sag magnitudes for any fault location algorithm that uses voltage information measured at a limited set of nodes along the feeder. An overhead, three-phase, three-wire, 13.8 kV, 134-node, real-life feeder model is used to evaluate the algorithm. Tests show that the results of the fault location methodology were improved thanks to the new optimized allocation of the meters pinpointed using this methodology. © 2011 IEEE.en
dc.format.extent37-43-
dc.language.isoeng-
dc.sourceScopus-
dc.subjectfault location-
dc.subjectMonte Carlo methods and optimization methods-
dc.subjectOptimal allocation-
dc.subjectphasor measurement units (PMUs)-
dc.subjectElectric power-
dc.subjectElectric power distribution systems-
dc.subjectFault location-
dc.subjectFault location algorithms-
dc.subjectGeneral methodologies-
dc.subjectGreedy randomized adaptive search procedure-
dc.subjectMetaheuristic-
dc.subjectMonte Carlo Simulation-
dc.subjectOptimized allocation-
dc.subjectPhasor measurement unit-
dc.subjectPlacement model-
dc.subjectVoltage sags-
dc.subjectAlgorithms-
dc.subjectComputer simulation-
dc.subjectElectric load distribution-
dc.subjectElectric power distribution-
dc.subjectElectric power system interconnection-
dc.subjectElectric power transmission-
dc.subjectFeeding-
dc.subjectOptimization-
dc.subjectPhase measurement-
dc.subjectThermoelectric equipment-
dc.subjectUnits of measurement-
dc.subjectMonte Carlo methods-
dc.titleOptimal phasor measurement units placement for fault location on overhead electric power distribution feedersen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationUNESP-Univ. Estadual Paulista FEIS Electrical Engineering Department, Ilha Solteira, São Paulo, 15385-000-
dc.description.affiliationUnespUNESP-Univ. Estadual Paulista FEIS Electrical Engineering Department, Ilha Solteira, São Paulo, 15385-000-
dc.identifier.doi10.1109/TDC-LA.2010.5762858-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartof2010 IEEE/PES Transmission and Distribution Conference and Exposition: Latin America, T and D-LA 2010-
dc.identifier.scopus2-s2.0-79957548651-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.