DC FieldValueLanguage
dc.contributor.authorBraga, Carlos Isidoro-
dc.contributor.authorRezende, Mirabel Cerqueira-
dc.contributor.authorCosta, Michelle Leali-
dc.date.accessioned2014-05-27T11:25:57Z-
dc.date.accessioned2016-10-25T18:34:15Z-
dc.date.available2014-05-27T11:25:57Z-
dc.date.available2016-10-25T18:34:15Z-
dc.date.issued2011-08-01-
dc.identifierhttp://dx.doi.org/10.5028/jatm.2011.03021911-
dc.identifier.citationJournal of Aerospace Technology and Management, v. 3, n. 2, p. 179-192, 2011.-
dc.identifier.issn1984-9648-
dc.identifier.issn2175-9146-
dc.identifier.urihttp://hdl.handle.net/11449/72578-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/72578-
dc.description.abstractDespite the large use of differential scanning calorimetry (DSC) technique in advanced polymer materials characterization, the new methodology called DSC in high heating rates was developed. The heating rate during conventional DSC experiments varying from 10 to 20°C.min-1, sample mass from 10 to 15mg and standard aluminum sample pan weighting, approximately, 27mg. In order to contribute to a better comprehension of DSC behavior in different heating rates, this work correlates as high heating rate influences to the thermal events in DSC experiments. Samples of metallic standard (In, Pb, Sn and Zn) with masses varying from 0.570mg to 20.9mg were analyzed in multiples sample heating rate from 4 to 324°C. min-1. In order to make properly all those experiments, a precise and careful temperature and enthalpy calibrations were performed and deeply discussed. Thus, this work shows a DSC methodology able to generate good and reliable results on experiments under any researcher choice heating rates to characterize the advanced materials used, for example, for aerospace industry. Also it helps the DSC users to find in their available instruments, already installed, a better and more accurate DSC test results, improving in just one shot the analysis sensitivity and resolution. Polypropylene melting and enthalpy thermal events are also studied using both the conventional DSC method and high heating rate method.en
dc.format.extent179-192-
dc.language.isoeng-
dc.sourceScopus-
dc.subjectCalibration-
dc.subjectDSC-
dc.subjectHigh heating rate-
dc.subjectPolymers-
dc.subjectThermal analysis-
dc.subjectAdvanced materials-
dc.subjectAdvanced polymers-
dc.subjectEnthalpy calibration-
dc.subjectHigh heating rates-
dc.subjectSample heating-
dc.subjectThermal events-
dc.subjectAerospace industry-
dc.subjectCharacterization-
dc.subjectDifferential scanning calorimetry-
dc.subjectEnthalpy-
dc.subjectExperiments-
dc.subjectHeating rate-
dc.subjectLead-
dc.subjectPolypropylenes-
dc.subjectSensitivity analysis-
dc.subjectThermoanalysis-
dc.subjectTin-
dc.subjectHeating-
dc.titleMethodology for DSC calibration in high heating ratesen
dc.typeoutro-
dc.contributor.institutionInstituto Tecnológico de Aeronáutica-
dc.contributor.institutionInstituto de Aeronáutica e Espaço-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationInstituto Tecnológico de Aeronáutica, São José dos Campos/SP-
dc.description.affiliationInstituto de Aeronáutica e Espaço, São José dos Campos/SP-
dc.description.affiliationSão Paulo State University, Guaratinguetá/SP-
dc.description.affiliationUnespSão Paulo State University, Guaratinguetá/SP-
dc.identifier.doi10.5028/jatm.2011.03021911-
dc.rights.accessRightsAcesso aberto-
dc.identifier.file2-s2.0-82455189539.pdf-
dc.relation.ispartofJournal of Aerospace Technology and Management-
dc.identifier.scopus2-s2.0-82455189539-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.