You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/72774
Full metadata record
DC FieldValueLanguage
dc.contributor.authorde Vasconcellos, Luis Gustavo Oliveira-
dc.contributor.authorNishioka, Renato Sussumu-
dc.contributor.authorde Vasconcellos, Luana Marotta Reis-
dc.contributor.authorNishioka, Lea Nogueira Braulino de Melo-
dc.date.accessioned2014-05-27T11:26:06Z-
dc.date.accessioned2016-10-25T18:34:59Z-
dc.date.available2014-05-27T11:26:06Z-
dc.date.available2016-10-25T18:34:59Z-
dc.date.issued2011-11-01-
dc.identifierhttp://dx.doi.org/10.1590/S1678-77572011000600011-
dc.identifier.citationJournal of Applied Oral Science, v. 19, n. 6, p. 610-615, 2011.-
dc.identifier.issn1678-7757-
dc.identifier.issn1678-7765-
dc.identifier.urihttp://hdl.handle.net/11449/72774-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/72774-
dc.description.abstractObjectives: The present study used strain gauge analysis to perform an in vitro evaluation of the effect of axial loading on 3 elements of implant-supported partial fixed prostheses, varying the type of prosthetic cylinder and the loading points. Material and methods: Three internal hexagon implants were linearly embedded in a polyurethane block. Microunit abutments were connected to the implants applying a torque of 20 Ncm, and prefabricated Co-Cr cylinders and plastic prosthetic cylinders were screwed onto the abutments, which received standard patterns cast in Co-Cr alloy (n = 5). Four strain gauges (SG) were bonded onto the surface of the block tangentially to the implants, SG 01 mesially to implant 1, SG 02 and SG 03 mesially and distally to implant 2, respectively, and SG 04 distally to implant 3. Each metallic structure was screwed onto the abutments with a 10 Ncm torque and an axial load of 30 kg was applied at five predetermined points (A, B, C, D, E). The data obtained from the strain gauge analyses were analyzed statistically by RM ANOVA and Tukey's test, with a level of significance of p<0.05. Results: There was a significant difference for the loading point (p=0.0001), with point B generating the smallest microdeformation (239.49 με) and point D the highest (442.77 με). No significant difference was found for the cylinder type (p=0.748). Conclusions: It was concluded that the type of cylinder did not affect in the magnitude of microdeformation, but the axial loading location influenced this magnitude.en
dc.format.extent610-615-
dc.language.isoeng-
dc.sourceScopus-
dc.subjectBiomechanics-
dc.subjectDental implants-
dc.subjectDental prosthesis-
dc.subjectImplant-supported dental prosthesis-
dc.subjectchromium derivative-
dc.subjectanalysis of variance-
dc.subjectchemistry-
dc.subjectdental procedure-
dc.subjectdenture-
dc.subjecthuman-
dc.subjectmaterials testing-
dc.subjectmechanical stress-
dc.subjectmethodology-
dc.subjectsurface property-
dc.subjecttooth implantation-
dc.subjecttooth prosthesis-
dc.subjecttorque-
dc.subjectAnalysis of Variance-
dc.subjectChromium Alloys-
dc.subjectDental Abutments-
dc.subjectDental Implants-
dc.subjectDental Prosthesis Design-
dc.subjectDental Prosthesis, Implant-Supported-
dc.subjectDental Stress Analysis-
dc.subjectHumans-
dc.subjectMaterials Testing-
dc.subjectStress, Mechanical-
dc.subjectSurface Properties-
dc.subjectTorque-
dc.titleEffect of axial loads on implant-supported partial fixed prostheses by strain gauge analysisen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionInstitute of Science Technology - CETEC-
dc.description.affiliationDepartment of Dental Materials and Prosthodontics São José dos Campos Dental School São Paulo State University, São José dos Campos, SP-
dc.description.affiliationDepartment of Bioscience and Buccal Diagnosis São José dos Campos Dental School São Paulo State University, São José dos Campos, SP-
dc.description.affiliationDepartment of Mechanical Engineering Institute of Science Technology - CETEC, São José dos Campos, SP-
dc.description.affiliationUnespDepartment of Dental Materials and Prosthodontics São José dos Campos Dental School São Paulo State University, São José dos Campos, SP-
dc.description.affiliationUnespDepartment of Bioscience and Buccal Diagnosis São José dos Campos Dental School São Paulo State University, São José dos Campos, SP-
dc.identifier.doi10.1590/S1678-77572011000600011-
dc.identifier.scieloS1678-77572011000600011-
dc.rights.accessRightsAcesso aberto-
dc.identifier.file2-s2.0-84855818872.pdf-
dc.relation.ispartofJournal of Applied Oral Science-
dc.identifier.scopus2-s2.0-84855818872-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 