You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/72839
Full metadata record
DC FieldValueLanguage
dc.contributor.authorCosta, E. C M-
dc.contributor.authorMonteiro, J. H A-
dc.contributor.authorPinto, A. J G-
dc.contributor.authorKurokawa, S.-
dc.contributor.authorFranco, J. L.-
dc.contributor.authorPissolato, J.-
dc.date.accessioned2014-05-27T11:26:14Z-
dc.date.accessioned2016-10-25T18:35:50Z-
dc.date.available2014-05-27T11:26:14Z-
dc.date.available2016-10-25T18:35:50Z-
dc.date.issued2011-12-01-
dc.identifierhttp://dx.doi.org/10.1049/cp.2011.0533-
dc.identifier.citationIET Conference Publications, v. 2011, n. 580 CP, 2011.-
dc.identifier.urihttp://hdl.handle.net/11449/72839-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/72839-
dc.description.abstractThis article shows an analysis of the electrical parameters of a three-phase transmission line section using a relatively new design for steel towers characterized by 280 meters high. These main features, the height of the line conductors and distance between them, are intrinsically related to the longitudinal and transversal parameters of the line. By this means, an analysis was carried out in order to show the electrical variations between a transmission line using the new technology and a conventional 440-kV line through a wide range of frequencies and a variable soil resistivity. © 2012 The Institution of Engineering and Technology.en
dc.language.isoeng-
dc.sourceScopus-
dc.subjectBrazilian electric system-
dc.subjectLine parameters-
dc.subjectTall towers-
dc.subjectTransmission line-
dc.subjectElectric systems-
dc.subjectElectrical parameter-
dc.subjectElectrical variations-
dc.subjectLine conductors-
dc.subjectNew design-
dc.subjectSoil resistivity-
dc.subjectSteel towers-
dc.subjectTransmission systems-
dc.subjectElectric lines-
dc.subjectPhase meters-
dc.subjectTransmission line theory-
dc.subjectReliability analysis-
dc.titleA First approach on the new transmission system in northern Brazilen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual de Campinas (UNICAMP)-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationUnicamp - University of Campinas-
dc.description.affiliationUnesp - Univ. Estadual Paulista School of Engineering of Ilha Solteira-
dc.description.affiliationUnespUnesp - Univ. Estadual Paulista School of Engineering of Ilha Solteira-
dc.identifier.doi10.1049/cp.2011.0533-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofIET Conference Publications-
dc.identifier.scopus2-s2.0-84858641252-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.