Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/72888
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | De Paiva Gonçalves, Sérgio Eduardo | - |
dc.contributor.author | Burim, Rafael Augusto | - |
dc.contributor.author | Pleffken, Patrícia Rondon | - |
dc.contributor.author | Barcellos, Daphne Câmara | - |
dc.contributor.author | Gomes, Ana Paula Martins | - |
dc.contributor.author | Huhtala, Maria Filomena Rocha Lima | - |
dc.date.accessioned | 2014-05-27T11:26:15Z | - |
dc.date.accessioned | 2016-10-25T18:35:56Z | - |
dc.date.available | 2014-05-27T11:26:15Z | - |
dc.date.available | 2016-10-25T18:35:56Z | - |
dc.date.issued | 2011-12-01 | - |
dc.identifier | http://dx.doi.org/10.1590/S1980-65232011000400007 | - |
dc.identifier.citation | Revista Odonto Ciencia, v. 26, n. 4, p. 315-320, 2011. | - |
dc.identifier.issn | 0102-9460 | - |
dc.identifier.issn | 1980-6523 | - |
dc.identifier.uri | http://hdl.handle.net/11449/72888 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/72888 | - |
dc.description.abstract | Purpose: The objective of this study was to evaluate the influence of the Grander technology in reducing the surface tension and contact angle of a self-etch adhesive system. Methods: Distilled water and Xeno III self-etch adhesive system (Dentsply) were modified by physical contact with the Flexible unit Grander system to revitalize water, for 48 hours, resulting in four groups: Group 1 - Xeno III under normal conditions; Group 2 - Xeno III modified by Grander; Group 3 - distilled water under normal conditions; Group 4 - distilled water system modified by the Grander system;. Surface tension and contact angle (dentin substrate and titanium plate) of the adhesive system and water in normal and Grander-modified conditions was measured with a goniometer. Data were analyzed by ANOVA and Tukey test (5%). Results: Grander technology reduced the surface tension of water but not of the adhesive system Xeno III. The contact angle property of the adhesive ystem was not affected. Conclusion: Grander technology did not interfere with the surface tension and contact angle physical properties of the Xeno III self-etch adhesive system. Copyright: © 2011 Gonçalves et al.;. | en |
dc.format.extent | 315-320 | - |
dc.language.iso | eng | - |
dc.source | Scopus | - |
dc.subject | Dentin | - |
dc.subject | Surface tension | - |
dc.title | A comparative study of the physical properties of conventional and Grander-modified adhesive systems | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.description.affiliation | São José Dos Campos School of Dentistry UNESP São Paulo State University, Avenida Engenheiro Francisco Jose Longo, São José Dos Campos, SP 12245-000 | - |
dc.description.affiliationUnesp | São José Dos Campos School of Dentistry UNESP São Paulo State University, Avenida Engenheiro Francisco Jose Longo, São José Dos Campos, SP 12245-000 | - |
dc.identifier.doi | 10.1590/S1980-65232011000400007 | - |
dc.identifier.scielo | S1980-65232011000400007 | - |
dc.rights.accessRights | Acesso aberto | - |
dc.identifier.file | 2-s2.0-84859734700.pdf | - |
dc.relation.ispartof | Revista Odonto Ciência | - |
dc.identifier.scopus | 2-s2.0-84859734700 | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.