You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/73308
Full metadata record
DC FieldValueLanguage
dc.contributor.authorRodrigues, Antonio Carlos Lottelli-
dc.contributor.authorTrivedi, Rupal H.-
dc.contributor.authorWilson, M. Edward-
dc.date.accessioned2014-05-27T11:26:29Z-
dc.date.accessioned2016-10-25T18:37:04Z-
dc.date.available2014-05-27T11:26:29Z-
dc.date.available2016-10-25T18:37:04Z-
dc.date.issued2012-05-01-
dc.identifierhttp://dx.doi.org/10.3928/01913913-20110920-02-
dc.identifier.citationJournal of Pediatric Ophthalmology and Strabismus, v. 49, n. 3, p. 157-163, 2012.-
dc.identifier.issn0191-3913-
dc.identifier.urihttp://hdl.handle.net/11449/73308-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/73308-
dc.description.abstractPurpose: To report the surgical technique and outcomes of a no-ring approach to posterior chamber intraocular lens (IOL) implantation in children and young adults with subluxation of the crystalline lens. Methods: A three-piece 5.5-mm hydrophobic acrylic IOL was implanted in which the optic and one haptic were inside the capsular bag and the other haptic was in the ciliary sulcus. The implantations were done in 13 eyes of 10 patients with lens subluxation. One haptic was fixated in the ciliary sulcus by passing it through an operculum-shaped opening in the capsular bag edge, made between 2 and 3 clock hours, clockwise from the middle point of the subluxated area. Results: The mean age of the 10 patients was 12.61 ± 8.04 years and the mean follow-up was 21.38 ± 11.29 months. The mean preoperative and postoperative best-corrected visual acuity (BCVA) was 1.15 ± 0.58 and 0.37 ± 0.17 logarithm of the minimum angle of resolution, respectively, in 11 measured eyes. The postoperative BCVA was 20/40 or better in 4 eyes (36.36%), between 20/40 and 20/60 in 6 eyes (54.54%), and between 20/80 and 20/100 in 1 eye (9.09%). The BCVA improved in all eyes. Postoperative IOL decentration between 1.0 and 1.5 mm occurred in 3 of 13 eyes (23.08%). Conclusion: The results indicate that the no-ring technique allows centration of an IOL implanted into a subluxated capsular bag without using capsule tension rings. © SLACK Incorporated.en
dc.format.extent157-163-
dc.language.isoeng-
dc.sourceScopus-
dc.subjectadolescent-
dc.subjectadult-
dc.subjectalgorithm-
dc.subjectcapsule opacification-
dc.subjectcapsulorhexis-
dc.subjectchild-
dc.subjectclinical article-
dc.subjectfemale-
dc.subjectfollow up-
dc.subjecthuman-
dc.subjecthydrophobicity-
dc.subjectlens implantation-
dc.subjectlens subluxation-
dc.subjectmale-
dc.subjectoperculum (brain)-
dc.subjectoutcome assessment-
dc.subjectposterior eye chamber-
dc.subjectpostoperative period-
dc.subjectpreoperative period-
dc.subjectretrospective study-
dc.subjectschool child-
dc.subjectsurgical technique-
dc.subjectvisual acuity-
dc.titleSubluxation of the crystalline lens: A no-ring approachen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionStorm Eye Institute-
dc.description.affiliationDepartment of Ophthalmology Botucatu Medical School Universidade Estadual Paulista, Botucatu, São Paulo-
dc.description.affiliationMiles Center for Pediatric Ophthalmology Storm Eye Institute Department of Ophthalmology, Medical University of South Carolina, Charleston, SC-
dc.description.affiliationUnespDepartment of Ophthalmology Botucatu Medical School Universidade Estadual Paulista, Botucatu, São Paulo-
dc.identifier.doi10.3928/01913913-20110920-02-
dc.identifier.wosWOS:000305209400005-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofJournal of Pediatric Ophthalmology and Strabismus-
dc.identifier.scopus2-s2.0-84862510634-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.