You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/73707
Full metadata record
DC FieldValueLanguage
dc.contributor.authorDe Freitas, S. C L-
dc.contributor.authorDe Oliveira, L. C O-
dc.contributor.authorDe Souza, J. B.-
dc.date.accessioned2014-05-27T11:27:08Z-
dc.date.accessioned2016-10-25T18:38:57Z-
dc.date.available2014-05-27T11:27:08Z-
dc.date.available2016-10-25T18:38:57Z-
dc.date.issued2012-11-01-
dc.identifierhttp://dx.doi.org/10.1109/TDC.2012.6281556-
dc.identifier.citationProceedings of the IEEE Power Engineering Society Transmission and Distribution Conference.-
dc.identifier.issn2160-8555-
dc.identifier.issn2160-8563-
dc.identifier.urihttp://hdl.handle.net/11449/73707-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/73707-
dc.description.abstractThe intent of this paper is to present contributions focused on the analysis and development of harmonic attenuator devices. Among these, highlights here the so-called electromagnetic zero-sequence suppressor. This arrangement consists of a filter and a blocker, both electromagnetic, whose combined operation provides paths for low and high impedance, respectively, which can be conveniently adjusted to the desired performance. In this context, here are present results related to experimental studies that show the behavior of the equipment in front of different operating conditions. The tests were performed on a low-power prototype (1kVA/220V) and the analysis results show the main motivator aspects for the use of these devices. © 2012 IEEE.en
dc.language.isoeng-
dc.sourceScopus-
dc.subjectelectromagnetic suppressor-
dc.subjectexperimental analysis-
dc.subjectzero-sequence harmonics-
dc.subjectCombined operations-
dc.subjectExperimental analysis-
dc.subjectExperimental studies-
dc.subjectHigh impedance-
dc.subjectLow Power-
dc.subjectOperating condition-
dc.subjectExhibitions-
dc.subjectElectromagnetism-
dc.titleExperimental analysis of an electromagnetic zero-sequence suppressoren
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationFEIS-UNESP-
dc.description.affiliationUniversity of São Paulo State (UNESP) Ilha Solteira, SP-
dc.description.affiliationUnespFEIS-UNESP-
dc.description.affiliationUnespUniversity of São Paulo State (UNESP) Ilha Solteira, SP-
dc.identifier.doi10.1109/TDC.2012.6281556-
dc.identifier.wosWOS:000317001100148-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofProceedings of the IEEE Power Engineering Society Transmission and Distribution Conference-
dc.identifier.scopus2-s2.0-84867921612-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.