Você está no menu de acessibilidade

Utilize este identificador para citar ou criar um link para este item: http://acervodigital.unesp.br/handle/11449/74046
Registro de metadados completo
Campo DCValorIdioma
dc.contributor.authorde Araujo Antunes, Aline-
dc.contributor.authorVannini, Francieli Delatim-
dc.contributor.authorSilveira, Liciana Vaz de Arruda-
dc.contributor.authorBarretti, Pasqual-
dc.contributor.authorMartin, Luis Cuadrado-
dc.contributor.authorCaramori, Jacqueline Socorro Costa Teixeira-
dc.date.accessioned2014-05-27T11:27:25Z-
dc.date.accessioned2016-10-25T18:40:36Z-
dc.date.available2014-05-27T11:27:25Z-
dc.date.available2016-10-25T18:40:36Z-
dc.date.issued2012-12-04-
dc.identifierhttp://dx.doi.org/10.1007/s11255-012-0337-3-
dc.identifier.citationInternational Urology and Nephrology, p. 1-7.-
dc.identifier.issn0301-1623-
dc.identifier.issn1573-2584-
dc.identifier.urihttp://hdl.handle.net/11449/74046-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/74046-
dc.description.abstractPurpose: Malnutrition and fluid overload contribute to the poor cardiovascular prognosis of dialysis patients. Since bioelectrical impedance analysis is an option for the evaluation of body composition and for the monitoring of hydration state, it may assist in the identification of subjects at high cardiovascular risk. The objective of this study was to evaluate the association between bioelectrical impedance parameters and cardiovascular events. Methods: The association between bioelectrical impedance parameters and fatal and non-fatal cardiovascular outcome was evaluated in 145 dialysis patients. Results: The mean age of the population studied was 54.9 ± 15.4 years, 49.7 % were males, and 35.9 % had diabetes. Forty (27.6 %) patients developed cardiovascular events during the 16 months (8; 32) of follow-up. Comparison of patients with and without cardiovascular events revealed higher extracellular mass/body cell mass (ECM/BCM) and extracellular water/total body water ratios and higher C-reactive protein levels in the former. Survival analysis showed that an ECM/BCM ratio >1.2 and a phase angle <6° were associated with poor cardiovascular prognosis. Among nondiabetic patients, these parameters and capacitance were independently associated with cardiovascular events, suggesting that poor nutritional status and fluid overload are associated with the occurrence of these events. Conclusions: Phase angle, capacitance and ECM/BCM ratio are valuable parameters for the evaluation of cardiovascular prognosis, supporting the use of bioelectrical impedance for the clinical assessment of dialysis patients. © 2012 Springer Science+Business Media Dordrecht.en
dc.format.extent1-7-
dc.language.isoeng-
dc.sourceScopus-
dc.subjectBioelectrical impedance-
dc.subjectCardiovascular-
dc.subjectDialysis-
dc.subjectPrognosis-
dc.titleAssociations between bioelectrical impedance parameters and cardiovascular events in chronic dialysis patientsen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationDepartment of Internal Medicine, Botucatu Medical School São Paulo State University-UNESP, Botucatu, 18618-970-
dc.description.affiliationDepartment of Biostatistics, Institute of Bioscience São Paulo State University-UNESP, Botucatu, 18618-970-
dc.description.affiliationUnespDepartment of Internal Medicine, Botucatu Medical School São Paulo State University-UNESP, Botucatu, 18618-970-
dc.description.affiliationUnespDepartment of Biostatistics, Institute of Bioscience São Paulo State University-UNESP, Botucatu, 18618-970-
dc.identifier.doi10.1007/s11255-012-0337-3-
dc.identifier.wosWOS:000325696900018-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofInternational Urology and Nephrology-
dc.identifier.scopus2-s2.0-84870183315-
Aparece nas coleções:Artigos, TCCs, Teses e Dissertações da Unesp

Não há nenhum arquivo associado com este item.
 

Itens do Acervo digital da UNESP são protegidos por direitos autorais reservados a menos que seja expresso o contrário.