Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/74197
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Ravalli, A. | - |
dc.contributor.author | Pilon Dos Santos, G. | - |
dc.contributor.author | Ferroni, M. | - |
dc.contributor.author | Faglia, G. | - |
dc.contributor.author | Yamanaka, Hideko | - |
dc.contributor.author | Marrazza, G. | - |
dc.date.accessioned | 2014-05-27T11:27:29Z | - |
dc.date.accessioned | 2016-10-25T18:41:00Z | - |
dc.date.available | 2014-05-27T11:27:29Z | - |
dc.date.available | 2016-10-25T18:41:00Z | - |
dc.date.issued | 2013-01-01 | - |
dc.identifier | http://dx.doi.org/10.1016/j.snb.2012.10.017 | - |
dc.identifier.citation | Sensors and Actuators, B: Chemical, v. 179, p. 194-200. | - |
dc.identifier.issn | 0925-4005 | - |
dc.identifier.uri | http://hdl.handle.net/11449/74197 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/74197 | - |
dc.description.abstract | This paper describes the optimisation and the analytical performances of a label-free impedimetric immunosensor for the detection of tumour marker CA125 based on gold nanoparticles modified screen-printed graphite electrode. Experimental conditions of each step for the developed immunosensor were studied and optimised. The immunosensor response varied linearly (r2 = 0.996) with antigen concentration between 0 and 100 U/mL. The estimated detection limit was 6.7 U/mL. The electrochemical immunosensor allowed unambiguous identification of CA125, while no significant non-specific signal was detected in the case of all negative controls. The analytical usefulness of the impedimetric immunosensor was finally demonstrated analysing serum samples. © 2012 Elsevier B.V. All rights reserved. | en |
dc.format.extent | 194-200 | - |
dc.language.iso | eng | - |
dc.source | Scopus | - |
dc.subject | CA125 | - |
dc.subject | Gold nanoparticles | - |
dc.subject | Impedimetric immunosensor | - |
dc.subject | Screen-printed electrode | - |
dc.subject | Tumour marker | - |
dc.subject | Analytical performance | - |
dc.subject | Detection limits | - |
dc.subject | Electrochemical immunosensors | - |
dc.subject | Experimental conditions | - |
dc.subject | Gold Nanoparticles | - |
dc.subject | Impedimetric immunosensors | - |
dc.subject | Screen printed electrodes | - |
dc.subject | Gold | - |
dc.subject | Graphite electrodes | - |
dc.subject | Metal nanoparticles | - |
dc.subject | Tumors | - |
dc.subject | Immunosensors | - |
dc.title | New label free CA125 detection based on gold nanostructured screen-printed electrode | en |
dc.type | outro | - |
dc.contributor.institution | University of Florence | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.contributor.institution | CNR-IDASC | - |
dc.description.affiliation | Department of Chemistry Ugo Schiff University of Florence, Via della Lastruccia 3, 50019 Sesto Fiorentino, Florence | - |
dc.description.affiliation | Department of Analytical Chemistry São Paulo State University (UNESP), Rua Prof. Francisco Degni, 14800-900 Araraquara, SP | - |
dc.description.affiliation | SENSOR Laboratory - Department of Physics and Chemistry University of Brescia CNR-IDASC, Via Valotti 9, 25133 Brescia | - |
dc.description.affiliationUnesp | Department of Analytical Chemistry São Paulo State University (UNESP), Rua Prof. Francisco Degni, 14800-900 Araraquara, SP | - |
dc.identifier.doi | 10.1016/j.snb.2012.10.017 | - |
dc.identifier.wos | WOS:000316588100024 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | Sensors and Actuators B: Chemical | - |
dc.identifier.scopus | 2-s2.0-84880921300 | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.