Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/74439
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Rueda-Medina, Augusto C. | - |
dc.contributor.author | Padilha-Feltrin, Antonio | - |
dc.date.accessioned | 2014-05-27T11:28:16Z | - |
dc.date.accessioned | 2016-10-25T18:43:06Z | - |
dc.date.available | 2014-05-27T11:28:16Z | - |
dc.date.available | 2016-10-25T18:43:06Z | - |
dc.date.issued | 2013-01-31 | - |
dc.identifier | http://dx.doi.org/10.1109/TPWRS.2012.2202926 | - |
dc.identifier.citation | IEEE Transactions on Power Systems, v. 28, n. 1, p. 490-502, 2013. | - |
dc.identifier.issn | 0885-8950 | - |
dc.identifier.uri | http://hdl.handle.net/11449/74439 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/74439 | - |
dc.description.abstract | Traditionally, ancillary services are supplied by large conventional generators. However, with the huge penetration of distributed generators (DGs) as a result of the growing interest in satisfying energy requirements, and considering the benefits that they can bring along to the electrical system and to the environment, it appears reasonable to assume that ancillary services could also be provided by DGs in an economical and efficient way. In this paper, a settlement procedure for a reactive power market for DGs in distribution systems is proposed. Attention is directed to wind turbines connected to the network through synchronous generators with permanent magnets and doubly-fed induction generators. The generation uncertainty of this kind of DG is reduced by running a multi-objective optimization algorithm in multiple probabilistic scenarios through the Monte Carlo method and by representing the active power generated by the DGs through Markov models. The objectives to be minimized are the payments of the distribution system operator to the DGs for reactive power, the curtailment of transactions committed in an active power market previously settled, the losses in the lines of the network, and a voltage profile index. The proposed methodology was tested using a modified IEEE 37-bus distribution test system. © 1969-2012 IEEE. | en |
dc.format.extent | 490-502 | - |
dc.language.iso | eng | - |
dc.source | Scopus | - |
dc.subject | Distributed generators | - |
dc.subject | Distribution systems | - |
dc.subject | Markov models | - |
dc.subject | Monte Carlo method | - |
dc.subject | Multi-objective optimization | - |
dc.subject | Power generation | - |
dc.subject | Reactive power market | - |
dc.subject | Uncertainty | - |
dc.subject | Markov model | - |
dc.subject | Multi objective optimizations (MOO) | - |
dc.subject | Algorithms | - |
dc.subject | Commerce | - |
dc.subject | Distributed power generation | - |
dc.subject | Local area networks | - |
dc.subject | Markov processes | - |
dc.subject | Monte Carlo methods | - |
dc.subject | Multiobjective optimization | - |
dc.subject | Synchronous generators | - |
dc.subject | Reactive power | - |
dc.title | Distributed generators as providers of reactive power support - A market approach | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.description.affiliation | Universidade Estadual Paulista (UNESP-IlhaSolteira), São Paulo | - |
dc.description.affiliationUnesp | Universidade Estadual Paulista (UNESP-IlhaSolteira), São Paulo | - |
dc.identifier.doi | 10.1109/TPWRS.2012.2202926 | - |
dc.identifier.wos | WOS:000313965700052 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | IEEE Transactions on Power Systems | - |
dc.identifier.scopus | 2-s2.0-84872929251 | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.