You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/75025
Full metadata record
DC FieldValueLanguage
dc.contributor.authorGoiato, Marcelo Coelho-
dc.contributor.authorSantos, Daniela Micheline dos-
dc.contributor.authorBaptista, Gabriella Trunckle-
dc.contributor.authorMoreno, Amália-
dc.contributor.authorAndreotti, Agda Marobo-
dc.contributor.authorDekon, Stefan Fiuza de Carvalho-
dc.date.accessioned2014-05-27T11:28:48Z-
dc.date.accessioned2016-10-25T18:46:38Z-
dc.date.available2014-05-27T11:28:48Z-
dc.date.available2016-10-25T18:46:38Z-
dc.date.issued2013-04-01-
dc.identifierhttp://dx.doi.org/10.3109/03091902.2013.774444-
dc.identifier.citationJournal of Medical Engineering and Technology, v. 37, n. 3, p. 203-207, 2013.-
dc.identifier.issn0309-1902-
dc.identifier.issn1464-522X-
dc.identifier.urihttp://hdl.handle.net/11449/75025-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/75025-
dc.description.abstractThe purpose of this study was to investigate the effect of thermal cycling and disinfection on the microhardness of acrylic resins denture base. Four different brands of acrylic resins were evaluated: Onda Cryl, QC 20, Classico and Lucitone. Each brand of acrylic resin was divided into four groups (n = 7) according to the disinfection method (microwave, Efferdent, 4% chlorhexidine and 1% hypochlorite). Samples were disinfected during 60 days. Before and after disinfection, samples were thermal cycled between 5-55 °C with 30-s dwell times for 1000 cycles. The microhardness was measured using a microhardener, at baseline (B), after first thermal cycling (T1), after disinfection (D) and after second thermal cycling (T2). The microhardness values of all groups reduced over time. QC-20 acrylic resin exhibited the lowest microhardness values. At B and T1 periods, the acrylic resins exhibited statistically greater microhardness values when compared to D and T2 periods. It can be concluded that the microhardness values of the acrylic resins denture base were affected by the thermal cycling and disinfection procedures. However, all microhardness values obtained herein are within acceptable clinical limits for the acrylic resins. © 2013 Informa UK Ltd.en
dc.format.extent203-207-
dc.language.isoeng-
dc.sourceScopus-
dc.subjectAcrylic resins-
dc.subjectAgeing-
dc.subjectDisinfection-
dc.subjectHardness-
dc.subjectChlorhexidine-
dc.subjectDenture base-
dc.subjectDisinfection methods-
dc.subjectDwell time-
dc.subjectFour-group-
dc.subjectMicrohardness-
dc.subjectThermal cycling-
dc.subjectResins-
dc.subjectacrylic acid resin-
dc.subjectchlorhexidine-
dc.subjecthypochlorite-
dc.subjectcycling-
dc.subjectdenture base-
dc.subjectdisinfection-
dc.subjectmicrowave radiation-
dc.titleEffect of thermal cycling and disinfection on microhardness of acrylic resin denture baseen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationDepartment of Dental Materials and Prosthodontics Faculty of Dentistry of Araçatuba Universidade Estadual Paulista (UNESP), Araçatuba, São Paulo-
dc.description.affiliationUnespDepartment of Dental Materials and Prosthodontics Faculty of Dentistry of Araçatuba Universidade Estadual Paulista (UNESP), Araçatuba, São Paulo-
dc.identifier.doi10.3109/03091902.2013.774444-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofJournal of Medical Engineering and Technology-
dc.identifier.scopus2-s2.0-84876953371-
dc.identifier.orcid0000-0002-3800-3050pt
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.